Model Number: CNI330 60-80KVA
Nominal Capacity: 60 – 80KVA
Nominal Voltage: 380/400/415VAC
Maximum Input Voltage Range: +-20%
Nominal Frequency: 50/60HZ
Application field:
Power Plant DCS Control System
Boiler Safety Monitoring System
Steam turbine inspection
Bypass systems and other automatic protection devices
Petrochemical, natural gas, plastics, production lines
laboratory testing equipment
| Parameter | Specification |
|---|---|
| Item No : | CNI330 60-80KVA |
| Order(MOQ) : | 1 pcs |
| Payment : | T/T |
| Product Origin : | China |
| Color : | RAL7035 |
| Shipping Port : | Shenzhen |
| Lead Time : | 3-4 weeks |
| Weight : | 758-952 Kg |
Three Phase Output 60-80KVA Industrial Online UPS
Description
Industrial UPS are regarded as fully customized power supply systems for rugged environments and designed particularly to safeguard critical loads in industrial applications where voltage transients, created by degraded mains supply, can seriously damage both UPS and the critical load.
Application:
Petroleum, chemical industry, gas and power station and so on.
Key features:
• Adopt full digital control technology.
• Intelligent detection and monitoring function.
• Digitally control the static switch with zero switch.
• Full isolation between input and output.
• Super low output zero earth voltage.
• DC UPS isolated with utility power completely.
• Cubical design with power standard (customization).
• Multifunctional protection for over-voltage, under voltage, over current, short circuit and over temperature and so on.
• Large-screen LCD monitor with Chinese and English operation interface.
• Ultra-long 256 event record, user-friendly analysis and management to the situation of the power supply (touch screen display).
• Static bypass has a strong anti-overload capability.
Product advantages:
Adopting High-speed DSP Control
Adopting voltage and current stepping technology under CPU control, the rectifier of UPS has a soft start function. The input step is less than 15 seconds (adjustable), and the maximum impact current on the power grid does not exceed the rated current.
High Reliability
Built-in input transformer, output transformer, and bypass transformer realize complete Galvanic isolation. Instead of discrete IGBT and SCR components, we uses Modular IGBT and SCR in Rectifier and Inverter, bringing in extremely high reliability.
Advanced BMS
Intelligent battery management, comprehensive charge and discharge management of batteries, including charging voltage and current limiting, discharge cut-off voltage, extending battery lifetime 30%-50%.
Flexible customization
Industrial UPS can be customized according to the customer’s environment, including input and output voltage, phase, frequency, battery voltage, charging current and IP level of the cabinet, etc.
Integrated design
The entire machine adopts a less fuse design, using circuit breakers, contactors, and electronic static switches. The circuit protection technology is advanced, greatly improving the reliability of the entire machine.
Strong Impact Ability
Adopting pulse-by-pulse technology to ensure that the maximum short-circuit current does not exceed the allowable range of single pulse short time IGBT, a pulse-by-pulse current limiting scheme is adopted.
Suitable for harsh environments
It can be applied in harsh environmental conditions such as dust, pests, high-temperature conditions, and earthquake areas to protect your important production processes and systems.
Parallel operation
Advanced distributed active parallel technology can realize parallel operation of 6PCS UPS units without the need for centralized bypass cabinet.
High compatibility
Compatible with Lead Acid (vented/sealed), NiCd (vented/gas recombination) batteries and lithium batteries.
Production Pictures:
、


Other Service
Service hours: 9:00am-19:00pm (China time)
Product service:
1. Pre-sales consultation; After-sales worry-free.
2. Support ODM and OEM.
3. Online guidance and Technical support.
Product Warranty:
One year warranty period against the B/L date 45 days later.(Possible to extend the warranty period to three years by add money)
FAQ:
What is a UPS?
A UPS is an electrical device that provides continuous, conditioned, uninterrupted power to acritical AC load. It also provides isolation between the input and the output. It consists of aRectifier/Battery Charger, Battery System, and inverter. The Battery Charger converts incoming commercial/utility AC power to DC power. This power is then supplied both to a Battery system and an inverter. The inverter then converts this DC power back into AC power which is fed to the critical load(s). The Battery is an emergency DC supply that is connected in parallel with the output of the Battery Charger, and supplies the DC power to the inverter (without any switching) in the event that the incoming commercial power is lost or outside of specified tolerances.
A true UPS is an on-line system, which means that under normal operating conditions, the power flow is through the Battery Charger, then through the inverter to the load. This differs from off-line, or stand-by systems, which are designed such that under normal conditions, power for the load is supplied directly from the commercial power source, NOT through the inverter. Depending on the design, and cost, the power may be conditioned by means of a Voltage Regulating Transformer or Power Conditioner placed in the power path between the commercial power source and the load. In an off-line or standby system, the inverter only supplies power to the load if the utility power fails. The Battery then picks up the inverter load for a finite period of time (typically 15–20 minutes).
When the battery is depleted, the inverter will turn off, and the load will go down.
In order for a power supply to be considered a true UPS, it must accept three sources of power. The first source is the commercial, or utility, power that supplies AC power to the Battery Charger; the second is the Battery, which provides emergency DC power. The third source is a bypass, or alternate, AC source, which provides emergency AC power to the load if the inverter is unable to supply power, either because of an inverter failure, or a fault on the load. Under these conditions, the load would be automatically transferred to the bypass source via a static (electronic) transfer switch. The bypass source also supplies power in the event that the load is transferred manually from the inverter via a manual maintenance bypass switch.
A true on-line UPS is also referred to as a double conversion system. This means, as the name implies, that the power is converted twice. First it is converted from AC to DC at the Rectifier; then it is converted back from DC to AC at the inverter. Another common term is reverse transfer. This refers to the fact that the load, under certain conditions as described above (faults, equipment failure, or manual operation), is transferred back onto the commercial/utility power source.
Again, this differentiates it from an off-line system where, under normal operation, the load is powered from the utility source.
What is pulse-width-modulation (PWM)?
A PWM inverter employs high speed switching power devices to generate a series of “pulses” in the inverter bridge to “simulate” a sine wave. This signal is then filtered and fed to the load through a linear transformer. Due to the advanced technology behind the industrialized standard of using PWM inverters, it has a very tight voltage regulation during step loading and unloading be it 0–100%, 100–0%, 0–50%, 50–0% etc… of between 2–5% of nominal under any operating condition. Loads are not compromised due to step loading or unloading. Other technical benefits are higher efficiencies, smaller footprint, advanced metering/monitoring, and lower audible noise.
Technical Parameters:
| Model | CNI330-60KVA | CNI330-80KVA | |
| Capacity | 60KVA/48KW | 80KVA/64KW | |
| Input | |||
| Rated voltage | 380/400/415 Vac three-phase | ||
| Voltage range | ±20% | ||
| Frequency range | 50/60HZ±5% | ||
| Power factor | ≥0.8 | ||
| Current harmonic distortion | <5%with harmonic filter | ||
| Soft Start | 0-100% in 10″ | ||
| Bypass Input | |||
| Rated voltage | 380/400/415 Vac single-phase | ||
| Permitted voltage range | ±15%(selectable from ±10% to±25% from front panel) | ||
| Rated frequency | 50/60Hz | ||
| Permitted frequency range | ±2%(selectable from ±1% to 5% from front panel) | ||
| Standard features | BackFeed portection;split bypass line | ||
| Batteries | |||
| Type | Maintenance-free lead-acid VRLA AGM/GEL;NICd | ||
| Maximum recharge current(A) | 0.2 X C10 | ||
| DC Voltage | 384VDC | ||
| AC ripple voltage | <1% | ||
| Inverter output | |||
| Number of phases | 3+N | ||
| Rated voltage(V) | 380/400/415Vac | ||
| Regulation of the output voltage | 348~424Vac phase/neutral(from control panel) | ||
| Crest factor(Ipeak/Irms) | 3:01 | ||
| Static stability | ±1% | ||
| Dynamic stability | ±5% | ||
| Frequency | 50/60Hz configurable | ||
| Overload | 110% 125% 150% of the rated current for 5h/10’/1′ | ||
| Frequency stability | ±0.05% on mains failure;±2%(selectable from ±1% to ±5%)with mains supply present | ||
| System | |||
| Remote signaling | Volt free contacts | ||
| Remote controls | EPO and Bypass | ||
| Communication | RS232+romote contacts | ||
| Operation temperature | 0℃/+40℃ | ||
| Relative humidity | <95% non condensing | ||
| Colour | Light grey (RAL7035) | ||
| Noise | 50-80dBA at 1m | ||
| Protection degree | IP42 | ||
| Efficiency Smart Mode | up to 98% | ||
| Compliance | Safty: EN 62040-1-1(Directive 2006/95/EC);EMC:6200-2(Directive 2004/108/EC) | ||
| Weight(KG)N.W | 758 | 952 | |
| Dimension W*D*H(mm) | 800*800*1900(2050) | ||
Partner with CONSNANT to find the perfect power system for your business. Our technical team is ready to provide customized solutions to optimize power usage and maximize efficiency.