products

Hybrid Telecom Power System 48VDC 300A 600A1 Hybrid Telecom Power System 48VDC 300A 600A2 Hybrid Telecom Power System 48VDC 300A 600A3 Hybrid Telecom Power System 48VDC 300A 600A4 Hybrid Telecom Power System 48VDC 300A 600A5 Hybrid Telecom Power System 48VDC 300A 600A6 Hybrid Telecom Power System 48VDC 300A 600A7

Hybrid Telecom Power System 48VDC 300A/600A

share

Facebook
LinkedIn

Model Number: OD-TRSS-48300/OD-TRSS-48600
Input AC voltage range:176Vdc~300Vac
Output DC voltage range: -43.2Vdc~ -57.6Vdc (Typical value-53.5Vdc)
Storage temperature Range: -45℃~+70℃

Application field:
Communication Base Station

Item No : OD-TRSS-48300/OD-TRSS-48600
Order(MOQ) : 10 pcs
Payment : T/T
Product Origin : China
Color : RAL7035
Shipping Port : Shenzhen
Lead Time : 3 weeks
Weight : 100 Kg

Hybrid Telecom Power System 48VDC 300A/600A

Description
OD-TRSS series telecom power system is an integrated solar telecom power supply that can be directly used outdoors.

Working Principle:
Normally,the power system runs in a parallel floating charge state,that is,the rectifier module,solar module,load,and battery work in parallel.Solar modules and rectifier modules provide floating charge current for power communication devices and batteries.If the output power of the solar module is insufficient to feed all the loads,the rectifier module will provide supplementary power for the communication devices.

When the mains power is off,the rectifier module stops working.If the solar power supply is normal,the solar module will feed the communication devices and charge the battery.If the output power of the solar module is insufficient to feed all the loads,the battery will provide supplementary power for the communication devices.

When the mains power is off,the rectifier module stops working.If the solar energy fails at the same time,the communication devices will be powered by batteries.When the battery discharge continues for a period of time to the point of the generator start,.the monitor sends start signal to the generator.Generator provides AC input power for the rectifier module,then the rectifier can supply power to the communication devices again and charge the battery to compensate for the consumption.When reaching the stop point of the generator,the monitor unit sends out a stop signal to the generator,and the generator turns off.

Features:

Features Description
Module characteristic The solar module has maximum power point tracking function. The maximum power point tracking accuracy is over 99.5%
The rectifier module adopts active power factor compensation technology, the power factor value is up to 0.99
The maximum efficiency of rectifier module is over 93%
The maximum efficiency of the solar module is over 95%
The solar module and rectifier module have high power density
The solar module and the rectifier module adopt the non-destructive hot swap technology, that is Plug-and-Play. It takes less than one minute to replace the solar module and rectifier module
The solar module and the rectifier module have output over-voltage protection function, including hardware over-voltage protection and software over-voltage protection. And the software over-voltage protection has two modes for option: the first time over-voltage lockout mode, the fourth time over-voltage lockout mode
Battery management Perfect battery management: battery protection, and functions like automatic voltage regulating, stepless current limiting, battery capacity calculation, automatic equalization/float charge conversion, online battery test.
Light and electricity complementary management Perfect light/electricity complementary management function, which can achieve the priority of the solar power supply and and maximize the use of the solar energy
Power statistic Load electricity consumption, solar power generated energy, mains generated energy, DG generated energy, battery discharge, battery charge
Data record 90 days record of historical data, the historical data can be uploaded.
200 records of history alarm,
10 groups of battery test data
Alarm function Perfect fault protection and fault alarm functions
Network design Providing dry contact and other communication ports for network flexibility;
Enabling proximal end software upgrade and unattended operation
Humanized operation interface LCD is designed with 15 degrees angle, which is more intuitional and convenient for the user’s operation.
Query the operating parameters, statistics, and historical alarms of the system through the LCD.
Control the system manually through the LCD
Lightning Protection Perfect lightning protection design at AC and DC sides
Energy-saving design The system, in addition to the sleep energy-saving function of the rectifier module, also supports and gives priority to the use of solar energy input to the load, makes full use of solar energy, to achieve energy saving and reduce greenhouse gas emissions
Outdoor type The system protection level is up to IP55, can be used outdoors. The system is compact and easy to install
System All the equipment in the system support the maintenance at the front
The system adopts rectifier module sleep technology, dual steady state contactor, low-power shunt and fan speed adjustable technology, and has more prominent energy-saving function
The optional AC heater makes the system work in low temperature reliably
Remote monitoring The Modem is configured with GPRS function which can realize remote monitoring through providing data to the Internet server
Application field
• Communication Base Station

Technical Specifications:

Model OD-TRSS-48300 OD-TRSS-48600
Cabinet Size(mm) W*D*H=759*693*1430(without air-conditioner)

W*D*H=759*817*1430(with air-conditioner)

W*D*H=759*693*1430(without air-conditioner)

W*D*H=759*817*1430(with air-conditioner)

User equipment space(U) Height: 17U; Width: 15U Height: 15U; Width: 15U
Weight (kg) N.W :130 kg N.W :160 kg
Rectifier module Number (pcs) 1-6 pcs(Optional) 1-12 pcs(Optional)
Size(mm) Individual module: W*D*H=106.5*286*41.5(±0.5mm)
Weight (kg) < 1.75 kg (Individual module)
Solar MPPT module

 

Number (pcs) 1-6pcs(Optional) 1-12 pcs(Optional)
Size(mm) Individual module: W*D*H=106.5*286*41.5(±0.5mm)
Weight (kg) < 1.75 kg (Individual module)
AC Input characteristics
AC input rated voltage Single-phase 220Vac / three-phase 380Vac Single-phase 220Vac / three-phase 380Vac
AC-input voltage range 176Vdc~300Vac (Full of work) 176Vdc~300Vac (176-275Vac@ system output rated capacity.)
AC input maximum current 40A (1 phase, the most power supply: 2 modules) 80A (One phase can control up to 4 modules)
AC input voltage frequency 45~65Hz (Typical value 50 / 60Hz )
AC power factor ≥0.99 (220 Vac rated load)
Input current harmonics ≤3% (220 Vac)
Midline current <30% phase line current (In three-phase balanced system)
PV Input characteristics
Pv module input 120Vdc ~ 425Vdc (Starting voltage over 160Vdc)
Pv-rated input voltage 340Vdc
MPPT voltage range 120Vdc to 340Vdc
Maximum input current of PV module 17A
Photovoltaic module reverse pole protection Wrong input polarity, no damage
Photovoltaic module input protection Positive and negative insurance
PV maximum input voltage 450Vdc (Power supply not be damaged)
Output characteristics
Rectifier output voltage range -43.2Vdc~ -57.6Vdc (Typical value-53.5Vdc)
Rectifier output maximum power 18kW 36kW
PV output voltage range -42Vdc~ -58Vdc (Typical value-54.5Vdc)
Voltage stabilization accuracy ≤±1%
Output ripple & noise ≤200mVp-p (Rated input voltage and load and bandwidth limit of 20 MHz) ≤100mVp-p (Rated input voltage and load and bandwidth limit of 20 MHz)
Current-sharing imbalance ≤±5% (Within the 50- -100% load range) ≤±3% (Within the 50- -100% load range and when there is no monitoring, the modules can autonomously share current.)
Rectifier module efficiency ≥93% ,≥95%,≥96% (220 Vac / rated load) ≥94% (220Vac/100% load rate)
PV module efficiency ≥96%
Startup time 3~10S (The rated input voltage starts to the output voltage establishes to the setting value, the starting output needs to use the pre-flow limit function)
On/off overshoot amplitude ≤±5% (When either module is hot plugged (the load current should not be greater than the total output current in the working module), the system output voltage fluctuates) ≤±3% (When either module is hot plugged (the load current should not be greater than the total output current in the working module), the system output voltage fluctuates)
Dynamic response

 

Overshoot range ≤±5% (25% -50% -25% or 50% -75% -50% load change) ≤±1% (25% -50% -25% or 50% -75% -50% load change)
Recovery time ≤200µS (25% -50% -25% or 50% -75% -50% load change) ≤10µS (25% -50% -25% or 50% -75% -50% load change)
Temperature coefficient ≤±0.02%/℃ ≤±0.02%/℃ (The difference between the DC output voltage and the output voltage setting value when the temperature changes by 10°C should not exceed ±0.02% of the output voltage setting value.)
Psophometrically weighted noise voltage ≤2mV
Wide-band noise voltage

 

3.4~150KHz ≤50mV ≤3mV
0.15~30MHz ≤20 ≤5mV
Discrete noise voltage

 

 

 

3.4~150KHz ≤5mV ≤2mV
150~200KHz ≤3mV ≤1mV
200~500KHz ≤2mV ≤1mV
0.5~30MHz ≤1mV ≤1mV
Voltage drop ≤500mV
Protection characteristics
AC input overvoltage protection 300Vdc (Can self-recovery, the difference of not less than 10 Vac)
AC input undervoltage protection 85Vdc (Can self-recover with a return difference of not less than 5 Vac) 80Vdc (Can self-recover with a return difference of not less than 5 Vac)
Photovoltaic input overvoltage protection 430Vdc (Can self-recovery, the difference of not less than 15 Vac)
Photovoltaic input undervoltage protection 110Vdc (Can self-recovery, the difference of not less than 40 Vac)
Rectifier output overvoltage protection -59Vdc~-61Vdc (Lock, can not recover, need to restart)  -58.5Vdc~-60.5Vdc (Locked)
Photovoltaic output overvoltage protection Internal-58.5 to-60.5Vdc, External: 63Vdc (Lock, can not recover, need to restart)
Output undervoltage protection Battery disconnect protection (Through monitoring, the battery can be powered down, and the protection point can be set)
Output limit protection Have Have (Output current limiting range: adjusted between 20% and 110% of the nominal current value)
Output short circuit protection Have (Long-term short circuit, can recover from itself)
Overtemperature protection It can recover automatically at the ambient temperature of 75℃. It can recover automatically at the ambient temperature of 65℃.
Battery polarity is connected to reverse protection Not have (According to the user needs can have the battery polarity reverse connection protection function)
Battery manual power-off protection Not have
PV underpower protection Input power <50W and shutdown for 5 minutes (The module starts when the input voltage is greater than 160 Vdc for 5 minutes.)
Environmental
Operating temperature -40℃-50℃ -15℃-45℃
Storage temperature -45℃-70℃ -40℃-70℃
Relative humidity 5%-95%
Altitude(m)  ≤4000m (3000~4000m capacity derated output)

Related products

IP56 Outdoor Industrial UPS 6 10KVA with cabinet air conditioner1
IP56 Outdoor Industrial UPS 6-10KVA with cabinet air conditioner
Three Phase Output Industrial Online UPS 160 300KVA
Three Phase Output Industrial Online UPS 160-300KVA
consnant.com ip55 floor mount outdoor ups 1 10kva with vrla battery1
IP55 floor mount outdoor UPS 1-10KVA with VRLA battery
Three Phase Output Industrial Online UPS 100 120KVA (5)
Three Phase Output Industrial Online UPS 100-120KVA

Related Articles

NEWS 3
Shenzhen CONSNANT Technology Co., Ltd. team building activities Huizhou trip.
NEWS 2
CONSNANT 10th Anniversary Celebration
NEWS 1
CONSNANT Team Building & Annual Meeting Activities

Contact us

Partner with CONSNANT to find the perfect power system for your business. Our technical team is ready to provide customized solutions to optimize power usage and maximize efficiency.

Solution5 1