SOLUTION

Modular Online UPS System Solution in Data Center

Solution Overview
Digital infrastructure expansion drives exponential growth of IDC, cloud computing base, enterprise server room and edge data node power demands. Traditional monolithic UPS faces rigid fixed capacity, full-machine shutdown maintenance, high idle upfront investment and low light-load efficiency, which cannot match Tier III/Tier IV high-availability standards and green low-carbon data center construction targets.
CONSNANT completes full matrix modular online UPS lineup covering CNME331 embedded compact series, CNM330 large vertical cabinet series, CNM331 high-power centralized bypass series , capacity range from 60kVA up to 1200kVA, all adopting three-in three-out high-frequency double-conversion online topology, full DSP digital distributed control, universal hot-swappable power module and N+X redundant architecture. The full product line satisfies power protection requirements from small branch server rooms to super-large carrier-grade IDC, delivering three core values: zero interruption business continuity, phased capacity expansion to cut TCO, intelligent energy-saving and simplified operation & maintenance.

 

1. CNME331 Embedded Modular UPS (60–150kVA) – Small & Medium Edge Data Node

Compact stacked embedded design, oriented to small server room, finance branch, medical information center, broadcasting station, edge communication node.
  • Rated capacity: 60–150kVA, single module small power, flexible combination
  • Ultra-wide input voltage window: 138~485Vac; 305–485Vac full power without derating, 138–305Vac linear power derating, strong anti-grid fluctuation capability
  • Output standard three-phase voltage: 380/400/415Vac, voltage precision ≤±1%, THDV ≤2% under linear load
  • Transfer time: 0ms from mains to battery, 0ms mains to bypass, no power interruption for IT load
  • Application scope: Small server room, banking, transportation monitoring, healthcare, petrochemical production control, medium-small substation

2. CNM330 Vertical Cabinet Modular UPS (50–800kVA) – Medium & Large IDC Core Room

Integrated tall cabinet structure, independent centralized bypass, support top/bottom dual cable entry, standard/full configuration switch options (mains, bypass, maintenance, output switch).
  • Single module unit: 50kVA, cabinet expandable from 50kVA to max 800kVA
  • Nominal input voltage tolerance ±20%, input power factor ≥0.99, low harmonic pollution to municipal grid
  • System MTBF up to 250,000 hours, N+X arbitrary redundant configuration; N+2 redundancy achieves 99.999% system availability, fully meets Tier IV fault tolerance requirements
  • Battery voltage flexible optional: ±180V~±300Vdc (30–50pcs battery strings); three-stage intelligent charging, automatic charging current matching battery capacity, extend battery service life
  • Protection functions: EPO emergency power off, short-circuit whole-system holding, overload, over-temperature, fan fault, anti-bypass back-feed, lightning protection

3. CNM331 Centralized Bypass Modular UPS (100–1200kVA) – Super Large Cloud & Carrier Data Center

New-generation high-power flagship model, single module 100kW power factor 1.0, up to 12 modules per single cabinet, max capacity 1200kVA, support 4-cabinet parallel expansion to MW-level power.
  • Core technology: Three-level Vienna rectifier topology, maximum system efficiency up to 97%, intelligent module dormant rotation technology to maintain high efficiency under light load
  • Unbalanced load adaptability: Output supports complete three-phase unbalanced load operation, automatically balance grid input current, avoid single-phase overload of municipal power supply
  • Human-machine interaction: 10-inch color touch LCD, full visual status display, redundant module quantity configurable directly via panel
  • Shared battery parallel technology: Multiple parallel UPS cabinets share one battery group, reduce battery procurement & floor space cost
  • Communication expansion: Built-in CAN/RS485/FE interface, optional SNMP, dry contact relay card, seamless docking with DCIM data center intelligent management platform
  • Environmental adaptability: Operating temperature 0–40℃, noise ≤70dB at 1m distance, altitude ≤1500m without derating

 

Core Technical Advantages Customized for Data Centers

1. N+X Distributed Redundancy to Eliminate Single Point of Failure
Each power module integrates independent rectifier, inverter, charger and static bypass circuit, adopting decentralized control + centralized management architecture. Faulty modules are isolated automatically without disrupting load sharing of remaining units.
  • N+1 redundancy as standard for Tier III computer rooms to support live maintenance;
  • N+2 high redundancy recommended for Tier IV carrier IDCs to reach 99.999% power availability and fully avoid service interruption caused by single component failure;
  • Real-time alarm triggers when actual load exceeds set redundant capacity, while normal power supply is maintained within total cabinet capacity.
2. Full Hot-Swap Design for Minutes-Level Maintenance Without Shutdown
All power, monitoring and bypass modules support live hot plugging under full load:
  • No power cut to servers, storage, switches and other IT equipment during capacity expansion or faulty module replacement;
  • Conventional monolithic UPS requires over 4 hours full-unit power-off for maintenance, while CONSNAnt modular UPS limits MTTR within 15 minutes, drastically cutting outage risks and SLA compensation losses for multi-tenant IDCs;
  • Universal interchangeable modules within the same series for unified spare parts inventory, reducing operators’ stocking costs.
3. Phased Elastic Capacity Expansion to Cut Upfront Investment & Optimize TCO
As cloud, AI and big-data businesses iterate gradually and computing power of data centers grows incrementally, CONSNAnt modular UPS delivers a “pay-as-you-grow” model:
  1. Deploy minimal modules matching current loads at initial construction to avoid one-time investment in idle capacity;
  2. Insert new power modules directly into existing cabinets during business expansion, with no cabinet replacement, massive cable reworking or machine room reconstruction;
  3. Take the 600kVA CNM330 cabinet as an example: start with 300kVA (6×50kW modules), then add modules to full 600kVA later. Upfront capital expenditure is reduced by nearly 40% compared with purchasing full-capacity UPS at one time.

4. High-Efficiency Topology for Green Low-Carbon Data Centers

  • CNM331 3-level topology achieves peak efficiency of 97%; CNM330/CNME331 deliver system efficiency ≥96% under typical data center load rate of 50%–75%;
  • Intelligent dormant rotation control: automatically hibernate redundant modules under light loads to concentrate loads on fewer operating units for high-efficiency operation, lowering UPS self-loss and matching air-condition cooling power consumption;
  • Input power factor ≥0.99 with ultra-low harmonic distortion, reducing harmonic loss of power distribution cabinets and transformers, complying with domestic green data center PUE assessment and carbon reduction standards.

5. Ultra-Wide Grid Compatibility & Premium Clean Power Output

The full product line adapts to complex grid conditions of domestic and overseas data centers:
  • CNME331 with ultra-wide 138–485Vac input suits unstable municipal power at suburban edge nodes and remote branch sites;
  • CNM330/CNM331 tolerate ±20% nominal voltage fluctuation, maintaining stable operation under voltage sag, surge, flicker and harmonic interference;
  • Pure sine wave output with crest factor of 3:1 fully protects high-density GPU servers, all-flash storage, core switches and optical transmission equipment from grid damage.

6. Intelligent Visual O&M & Proactive Fault Early Warning

  • All cabinets are equipped with 7/10-inch touch LCD screens to real-time display input/output voltage, current, power, battery SOC, module operating status and historical fault logs;
  • Diversified communication expansion cards support remote cloud monitoring and linkage with DCIM management platforms to realize unattended machine room operation;
  • Early warnings for module overheating, battery aging, long-term overload and fan abnormalities convert passive emergency repair into predictive maintenance, reducing unplanned downtime frequency.

7. Flexible Mechanical & Wiring Design for Various Machine Room Layouts

  • CNM330 vertical cabinets support top and bottom cable entry; standard version (maintenance bypass only) and full version (complete input/output switches) optional;
  • CNME331 stacked compact units with casters for easy handling and layout in narrow small server rooms;
  • Standardized cabinet size with neat wiring and centralized power distribution, greatly simplifying civil engineering and electrical integration construction of data centers.

Solution Conclusion

Modular online UPS has become the standard power infrastructure for new-generation high-efficiency, elastic-scaling data centers, replacing traditional fixed-capacity monolithic UPS. CONSNAnt completes full capacity coverage with CNME331, CNM330 and CNM331 three product lines, integrating ultra-high reliability, flexible phased expansion, green energy-saving and intelligent O&M capabilities, covering all scenarios from edge small rooms to super-large carrier IDC.
For data center builders and operators, CONSNAnt modular UPS system realizes three core benefits: guarantee 7×24h core IT load continuous power supply to avoid business loss; cut upfront idle asset investment and long-term electricity & maintenance cost to lower full-lifecycle TCO; match green data center energy-saving and carbon reduction construction goals, deliver stable, scalable and cost-effective uninterrupted power protection for digital infrastructure.

Related images

Share This Post :
Facebook
Twitter
LinkedIn

Related products

No posts found

Contact us

Partner with CONSNANT to find the perfect power system for your business. Our technical team is ready to provide customized solutions to optimize power usage and maximize efficiency.

Related Articles

Outdoor Telecom Cabinet All-in-One Solution
CONSNANT Outdoor Telecom Cabinet All-in-One Solution
Outdoor Solar Power System Solution
Outdoor Solar Power System Solution For Traffic Lights
Industrial And Commercial Energy Storage System Solution
Industrial And Commercial Energy Storage System Solution
Battery System Application Solution
Battery System Application Solution
Solution5 1