SOLUTION

Low Frequency Online UPS System Solution for Medical Facilities

Solution Overview

Medical power security directly determines patient life safety and the accuracy of clinical diagnosis. Operating rooms, ICUs, radiology equipment, hospital HIS/PACS servers and laboratory instruments cannot tolerate grid surges, voltage fluctuations or power outages. Any power abnormality may trigger suspended surgery, distorted CT/MRI images, lost patient medical data, and even fatal risks for critically ill patients.

Consnant CNG310 (3Ph Input / 1Ph Output) & CNG330 (3Ph Input / 3Ph Output) Low Frequency Online UPS series delivers a full-spectrum medical-grade power protection solution, covering 10–800KVA power tiers as specified in the official product brochure. Adopting online double-conversion (VFI) topology with built-in output isolation transformer, IGBT power devices and full DSP microprocessor control, the series is certified by ISO, IEC and CE, fully complying with global medical electrical safety standards. It is widely deployed in community clinics, general hospitals and tertiary medical complexes to build an all-round stable power barrier for electro-medical equipment.

 

1. Core Power Challenges Faced by Medical Institutions

Combined with actual hospital operation scenarios and product technical specifications, medical facilities face four irreplaceable power demands that only low-frequency isolated UPS can solve:
  1. Zero-switch power backup for life-support equipmentVentilators, anesthesia machines, extracorporeal circulation devices and multi-parameter monitors require 0ms transfer time. Even millisecond power interruption will cut off real-time vital sign monitoring. Ordinary UPS with transfer delay cannot meet ICU and operating room standards.
  2. Anti-inrush & anti-interference protection for high-precision imaging equipmentCT, MRI, DR and linear accelerators generate massive instantaneous inrush current during startup, while grid harmonics and leakage current cause image artifacts. Built-in isolation transformer of low-frequency UPS suppresses common-mode noise and withstands 300% instantaneous overload, avoiding equipment shutdown and blurred scanning images.
  3. Leakage current isolation for patient contact zonesIEC medical electrical codes mandate galvanic isolation for wards where patients directly touch medical equipment. Transformerless high-frequency UPS cannot eliminate residual leakage current, bringing hidden electric shock risks.
  4. Complex unstable grid environment in medical buildingsHospital grids mix air conditioners, elevators, medical devices and industrial loads, resulting in ±20% wide voltage swing and high harmonic distortion. The CNG series features ±20% ultra-wide input voltage range and built-in EMI filters to adapt to aging hospital power distribution systems.

 

2. Consnant CNG310 & CNG330 Full Product Portfolio (From Official PDF Brochure)

The low-frequency UPS system is divided into two core models to match differentiated medical load requirements, with complete parameter data extracted from the official 10–800KVA product datasheet:

2.1 CNG310 Series: Three-phase Input, Single-phase Output (10–100KVA)

  • Capacity tiers: 10/15/20/30/40/60/80/100KVA, output power factor 0.9
  • Active power matching: 9KW–90KW, single-phase 220V clean output
  • Core medical positioning: Small clinics, single operating rooms, independent ICUs, ultrasound rooms, outpatient testing labs
  • Key brochure technical highlights:
    1. 6-pulse rectifier, input current distortion THDi<4%, avoiding grid resonance with hospital transformers and generators
    2. 0ms transfer time, linear load THDu≤3%, nonlinear load THDu≤5%, pure sine wave output
    3. Overload performance: 125% load sustain for 10 mins, 150% load sustain for 1 min with automatic recovery after load reduction
    4. Standard 7-inch touch LCD multi-language display, real-time data & 128-piece fault event log storage
    5. Operating temperature -10~35℃ without power derating, altitude adaption up to 4000m

2.2 CNG330 Series: Three-phase Input, Three-phase Output (10–800KVA)

  • Capacity tiers: 10–40KVA / 60–120KVA / 160–250KVA / 300–800KVA, output PF=0.9
  • Core medical positioning: Radiology centralized power supply, multi-operating room cluster, hospital IDC, central laboratory, tertiary hospital whole-building core power backbone

Exclusive brochure technical advantages for large medical projects:

  1. Support up to 6 units parallel redundant (N+1/N+X), hot system expansion without load power cut; communication cable disconnection will not crash parallel system (closed-loop architecture)
  2. Dual-bus dynamic redundant configuration & common bypass parallel architecture optional, fully isolating downstream load faults

    image
    6-unit parallel topology
    image
    Dual-bus dynamic redundant system
    image
    Dual bus UPS configuration
  3. Optional 12-pulse rectifier for high-capacity models (300KVA+), further reducing grid harmonic pollution
  4. Distributed bypass design: Single-unit maintenance will not interrupt the whole hospital core power supply
  5. Generator synchronization interface: Automatically adapt frequency/phase fluctuation of hospital backup diesel generators to extend battery service life

 

3. Medical-Oriented Exclusive Advantages (Supplemented by Brochure Technical Details)

3.1 Built-in Isolation Transformer, Fully Meet Medical IT Isolation Power Standards

Different from transformerless high-frequency UPS, every CNG series unit integrates a dedicated output isolation transformer, realizing complete galvanic separation between grid and medical loads. It thoroughly blocks common-mode interference and leakage current, complying with IEC60364-7-710 medical electrical specifications for operating rooms and ICUs, eliminating electric shock risks when patients touch diagnostic equipment directly.

3.2 Ultra-high Anti-inrush & Overload Capacity for Radiology Equipment

The low-frequency transformer structure delivers powerful magnetic buffer capacity, with crest factor up to 3:1, perfectly coping with the instantaneous high current of CT, MRI and linear accelerators during startup. Even with frequent equipment switching, the UPS will not trigger overload protection shutdown, ensuring continuous complete medical imaging data collection.

3.3 Zero Transfer Online Double Conversion, No Power Gap for Life-support Loads

Under normal mains power, medical loads are continuously powered by the inverter; when mains fails, battery power takes over within 0ms without any power interruption. Ventilators, anesthesia machines and defibrillators maintain uninterrupted operation, completely avoiding life safety accidents caused by power switching gaps.

3.4 Ultra-wide Grid Adaptability & Low Harmonic Pollution for Complex Hospital Grids

Input voltage fluctuation tolerance reaches ±20%, adapting to unstable municipal power in suburban hospitals and aging power distribution systems. The built-in multi-stage EMI filter and 6/12-pulse rectifier control input current distortion below 4%, which will not cause resonance with hospital transformers, capacitors and backup generators, reducing hospital power distribution cabinet investment costs.

3.5 Flexible Parallel & Hot Expansion for Hospital Capacity Iteration

CNG330 series supports up to 6 units in parallel, with mixed power capacity parallel allowed. Adopting masterless closed-loop parallel technology, even if one communication cable is disconnected, the whole system still runs stably. Hot system expansion realizes new UPS cabinet online access without cutting off hospital loads, suitable for hospital ward expansion and radiology equipment upgrading.

3.6 Complete Intelligent Battery Care System to Lower Hospital Operation Cost

Equipped with temperature compensation charging module, battery deep discharge lockout protection and one-click automatic battery test function from factory configuration. It effectively avoid battery damage caused by overcharging/over-discharging, prolong battery service life and reduce the frequency and cost of hospital battery replacement.

3.7 Rich Communication & Emergency Control Functions for Hospital Centralized Management

  • Standard EPO emergency power-off interface: Realize remote emergency shutdown linkage with hospital fire alarm system
  • Optional SNMP monitoring module: Real-time push of overload, low battery, over-temperature fault alarms to hospital central control room PC or mobile terminal
  • Built-in 128-group event storage log: Facilitate hospital power equipment regular inspection and fault traceability
  • Cross-platform monitoring software Watch & Save 3000 free provision, compatible with all mainstream operating systems of hospital servers

 

4. Targeted Medical Scenario Solution Configurations

4.1 Grassroots Clinic & Community Hospital (10–40KVA CNG310 3-in-1-out)

  • Protected loads: B-ultrasound, ECG, emergency rescue devices, nurse station HIS computer, small clinical analyzers
  • Configuration: Standalone CNG310 host + external battery cabinet, backup time 1–4 hours customizable
  • Matching brochure advantages: Compact cabinet size, single-phase 220V direct output without secondary distribution transformation, low investment threshold, easy installation for small medical power rooms

4.2 Independent Operating Room / ICU Ward (40–100KVA CNG310)

  • Protected loads: Operating table, anesthesia machine, ventilator, defibrillator, multi-parameter monitor, operating room lighting system
  • Configuration: Independent UPS dedicated to critical ward, optional dual-mains ATS switch to realize dual-grid input backup
  • Value: Isolate life-support loads from hospital public grid interference generated by elevators, central air conditioning and other equipment, ensure absolute power stability of rescue equipment

4.3 Radiology Imaging Department Centralized Power Supply (60–250KVA CNG330 3-in-3-out)

  • Protected loads: CT, MRI, DR, PET-CT, DSA, image post-processing workstation, film printing equipment
  • Configuration: Centralized three-phase UPS host, N+1 parallel redundant design for tertiary hospitals, independent distribution cabinet for each scanner
  • Core technical matching: 3:1 high crest factor and isolation transformer eliminate image noise artifacts, high overload resistance protects millions of high-value imaging equipment

4.4 Large Tertiary Hospital Whole Core Power Backbone (300–800KVA Multi-parallel CNG330)

  • Protected loads: Multi-operating room cluster, central ICU, full radiology equipment, hospital IDC data center, central laboratory, emergency building full loads
  • System architecture: 2–6 units CNG330 parallel redundant system, dual-bus dynamic backup optional, large-capacity battery group supporting 2–8 hours emergency power supply, SNMP centralized monitoring platform linked with hospital building automation system
  • Project advantage: Single-unit maintenance will not cut off overall power supply, meeting 24-hour uninterrupted medical service requirements of top tertiary hospitals

 

5. Installation & Operation Advantages

  1. Flexible wiring design: Rectifier input does not require neutral wire, can separate rectifier and bypass power supply from two independent municipal grids, simplifying hospital dual-power distribution transformation
  2. Wide environmental adaption: Normal full-power operation at -10~35℃, adapt to unair-conditioned basement power rooms of old hospitals; maximum altitude 4000m without power derating
  3. Low maintenance cost: Mature low-frequency circuit design with fewer high-frequency vulnerable components, long MTBF; large component design margin reduces annual maintenance frequency
  4. Complete certification system: Conform to GB, IEC 62040, EN62040 safety & EMC standards, obtain ISO, IEC, CE global certifications, meet medical engineering project bidding access requirements
  5. Customization support: Adjustable battery backup duration, lithium iron phosphate/lead-acid battery matching, cabinet size & monitoring function customized according to hospital power room layout

 

Solution Conclusion

Medical power protection is directly tied to patient life safety and medical diagnosis accuracy. Consnant CNG310 single-phase output and CNG330 three-phase output low-frequency online UPS series leverage transformer-isolated double-conversion low-frequency core technology to solve the unique power challenges of clinics, general hospitals and large tertiary medical complexes.
With complete capacity coverage, medical safety-oriented isolation design, strong anti-impact performance and intelligent remote management capabilities, Consnant Low Frequency Online UPS System provides a reliable, long-life and fully compliant all-scenario power guarantee solution for global medical facilities, building an unbreakable power safety barrier for every medical procedure and patient.

Related images

Share This Post :
Facebook
Twitter
LinkedIn

Related products

No posts found

Contact us

Partner with CONSNANT to find the perfect power system for your business. Our technical team is ready to provide customized solutions to optimize power usage and maximize efficiency.

Related Articles

Outdoor Telecom Cabinet All-in-One Solution
CONSNANT Outdoor Telecom Cabinet All-in-One Solution
Outdoor Solar Power System Solution
Outdoor Solar Power System Solution For Traffic Lights
Industrial And Commercial Energy Storage System Solution
Industrial And Commercial Energy Storage System Solution
Battery System Application Solution
Battery System Application Solution
Solution5 1