Solution Overview
Digital transformation, cloud computing, AI computing clusters and IDC infrastructure put forward ultra-high requirements for power continuity, power quality and space utilization. Power anomalies such as voltage sag, surge, harmonic interference and sudden blackout will directly lead to server downtime, data corruption and huge economic losses for data centersConsnant.
CONSNANT full-series high-frequency online UPS covering 1KVA–100KVA , classified by phase architecture (Single-Phase 1Ph/1Ph, Three-Phase 3Ph/1Ph & 3Ph/3Ph) and installation form (Tower vertical, Rack-mount 19-inch standard cabinet), adopts true double-conversion topology, DSP full-digital control and silicon carbide high-frequency power device technology. It forms a hierarchical, scalable, space-saving and high-efficiency power protection system, covering small branch server rooms, edge computing nodes, medium enterprise computer rooms and large core IDC data centers comprehensively
Core Technical Advantages of CONSNANT High-Frequency Online UPS for Data Centers
1. True Double Conversion, Zero Switching Power Protection
The whole machine runs on AC-DC-AC double conversion mode all the time. Servers, storage arrays and network switches are continuously powered by the inverter, with 0ms switching time when mains power fails, completely avoiding the restart risk of sensitive IT loads caused by power interruption. Pure sine wave output with THD<3% isolates all grid disturbances including spike, flicker, frequency drift and harmonic pollution, meeting the strict power supply standards of data center core equipment.
2. High Efficiency & Low TCO, Adapt to 24/7 Continuous Operation
Equipped with SiC silicon carbide diodes and high-frequency IGBT rectifier, the system efficiency reaches over 96% under AC mains mode and battery mode. Built-in active PFC circuit, input power factor up to 0.99, input current harmonic THDi<3%, reduces which the capacity configuration of front-end power distribution cabinets and diesel generators by about 15%, cutting the initial construction and long-term electricity cost of data centers.
3. Ultra-Wide Input Voltage Range, Strong Grid Adaptability
Different series match differentiated wide voltage windows to adapt unstable power environments of edge computer rooms, remote branch data centers and industrial supporting IDCs:
- 1–20KVA single/three-phase small models: 110–300VAC, rarely transfer to battery mode to extend battery cycle life
- 10–40KVA three-phase rack UPS: 138–476VAC
- 80–100KVA high-power three-phase tower UPS: dual-range 305–478VAC / 208–304VAC (derated operation for low voltage)
4. Flexible Parallel Redundancy & Scalable Capacity
Support N+1 parallel redundant expansion (up to 4 units parallel) and shared battery pack design. Small and medium data centers can realize hot standby power backup; large IDCs can carry out phased capacity expansion according to business growth without replacing the whole power system, realizing flexible investment and high reliability. Optional dual mains input function ensures uninterrupted power supply even if one main circuit failsConsnant.
5. Intelligent Monitoring & Predictive O&M
Large LCD blue backlight touch screen, real-time display of input/output voltage, load rate, battery status, temperature and fault logs. Built-in self-diagnosis algorithm to pre-warn hidden faults of fan, capacitor and battery; support RS485, SNMP network monitoring protocol, docking data center DCIM management platform to realize remote real-time monitoring, automatic alarm and unattended operation. ISO, IEC, CE international certifications guarantee stable operation in long-term continuous load environment.
Full Product Matrix: Classification by Phase & Installation Form (1–100KVA)
CONSNANT high-frequency online UPS divides the whole product line into single-phase and three-phase architectures, each equipped with Tower vertical and Rack-mount two installation forms, matching different data center space layout and load scale.
1. Single-Phase Series CNH110 (1–20KVA, 1Ph In / 1Ph Out) / CNH110L (1-3kVA, 1Ph In / 1Ph Out) Lithium online UPS
Suitable for small edge server rooms, office server clusters, bank branch computer rooms, ATM equipment and mini data center nodes with single-phase 220V loads.
♦ Tower Vertical Type (CNH110/ CNH110L Tower)
Capacity coverage: 1–3KVA / 6–10KVA / 10–20KVA
- Independent vertical cabinet with universal casters, placed freely on computer room floor, no cabinet transformation required
- Low noise design, suitable for office co-located small server rooms
- Independent battery compartment, convenient for external long-delay battery pack configuration
♦ Rack-Mount Type (CNH110R/ CNH110RL Rack)
Capacity coverage: 1–3KVA / 6–10KVA / 10–20KVA
- Standard 19-inch cabinet installation, ultra-high power density, saving valuable data center cabinet space
- Detachable support feet, flexible switching between rack and tower installation modes
- Integrated external battery slot design, neat wiring inside the cabinet for standardized IDC management
2. Three-Phase Series CNH310 / CNH330 (10–100KVA, 3Ph In /1Ph Out & 3Ph In /3Ph Out)
For medium and large enterprise core computer rooms, cloud computing IDCs, operator communication data centers and multi-server rack centralized power supply with three-phase 380/400/415VAC power distribution.
♦ Three-Phase Rack UPS CNH330R (10–40KVA, 3P/3P)
- Rack-mounted high-power three-phase UPS, installed in standard power distribution cabinet, realizing centralized power supply for multiple server cabinets
- Dual cooling fan honeycomb ventilation structure, strong heat dissipation to adapt high-density load continuous operation
- 40–70Hz wide frequency adaptation, compatible with generator backup power supply of data centers
♦ Three-Phase Tower UPS CNH330 Tower (10–20KVA /30–60KVA /80–100KVA, 3P/3P)
- Large vertical integrated cabinet, built-in independent battery area, supporting long-time backup configuration
- Heavy-duty movable casters + leveling foot pad, convenient for computer room layout adjustment
- Output power factor up to 1.0, fully matching high-power three-phase IT loads of core data centers
♦ 3Ph In /1Ph Out CNH310 Series (10–20KVA, 3P/1P)
Transition three-phase input single-phase output model, applied to medium computer rooms with three-phase incoming power but single-phase server loads, balancing three-phase grid load and simplifying power distribution design.
Why CONSNANT High-Frequency Online UPS Is the Preferred Power Solution for Data Centers
- Full capacity seamless coverage: Complete product line from 1KVA micro power to 100KVA high power, single/three-phase, rack/tower dual forms, one-stop matching all types of data center load demands without mixed brand matching
- High-frequency lightweight design: No bulky industrial frequency transformer, smaller volume and lighter weight, effectively saving the limited cabinet and power distribution room space of data centers, reducing air conditioning cooling load
- Green energy saving index: High full-load efficiency, low harmonic pollution, conform to national data center energy-saving and carbon reduction standards, reduce long-term operation power consumption expenditure
- High reliability redundant design: Double DSP chip control, multi-layer surge protection, wide voltage anti-interference, N+1 parallel backup to eliminate single-point power failure risk of data center core equipment
- Perfect intelligent O&M system: Standard DCIM docking interface, full lifecycle equipment health monitoring, reduce data center manual operation and maintenance pressure
- Global standard certification: ISO quality management, IEC electrical safety, CE electromagnetic compatibility certification, suitable for domestic and overseas data center engineering projects export matching
With the continuous expansion of data center business scale and the increasing complexity of power grid environment, a hierarchical, flexible, high-efficiency and reliable uninterruptible power supply system has become the core infrastructure guarantee.
CONSNANT 1–100KVA full-series high-frequency online UPS, with dual installation forms of tower and rack, single-phase & three-phase complete phase architectures, combined with double conversion high-frequency technology and intelligent digital control, provides customized power protection solutions for mini edge nodes, medium enterprise computer rooms and large core IDCs. It effectively avoids data loss and business interruption risks caused by power faults, helps data center operators build safe, energy-saving and easy-to-maintain power supply infrastructure, and realizes stable and continuous operation of all IT loads throughout the year.