CNW330 Series 10-40KVA IP55 Outdoor Industrial UPS With Air Conditioner

share

Facebook
LinkedIn

Model Number: CNW330 10-40KVA
Nominal Capacity: 10-40KVA
Nominal Voltage: 208VAC
Maximum Input Voltage Range: ±20%
Nominal Frequency: 50/60HZ

 

Item No : CNW330 10-40KVA
Order(MOQ) : 1
Payment : T/T
Product Origin : China
Color : RAL7035
Shipping Port : Shenzhen
Lead Time : 3 weeks
Weight : 273-602 Kg
Description
Field power supply projects always face tough troubles: no dedicated equipment room, extreme temperature, rain and dust erosion, frequent battery replacement costs, production loss caused by shutdown maintenance and unstable distorted grid power. The CNW330 series all-in-one outdoor UPS is developed to solve all above pain points, specially customized for unattended telecommunication base stations, traffic monitoring, oil & gas sites, photovoltaic measuring equipment and remote industrial control systems. Different from conventional indoor UPS, it adopts IP55 fully sealed anti-corrosion cabinet and built-in industrial air conditioner, supporting all-weather operation from -30℃ to +50℃ without extra room construction, cutting civil engineering cost by over 60%. We provide one-stop customized power solutions for both indoor and outdoor engineering projects to guarantee continuous power for precision loads.

Core Performance & Technical Advantages

Adopting mature online double-conversion topology, the unit achieves 0ms transfer time and pure sine wave output, isolating surge, voltage fluctuation and harmonic interference thoroughly. Equipped with intelligent rectifier module, it applies float charge + constant voltage equalized two-stage charging logic; charging current is limited to 15% of battery capacity, effectively slowing down battery aging and extending service life by 30% to cut long-term replacement expenses. Matched external battery pack instantly supplies backup energy once mains power fails to avoid equipment outage damage.
For sites with poor power quality, optional front harmonic reduction filter is available to lower current distortion and improve grid compatibility. The inverter runs 24/7 nonstop to deliver stable clean AC power. A high-speed static switch supports automatic & manual switching between inverter and bypass circuit, with exclusive SCR backfeed protection to eliminate current feedback risks and strengthen whole-system safety.

Humanized Maintenance Design

Fitted with independent SWMB maintenance bypass switch, the CNW330 series realizes zero-downtime overhaul. Operators can fully isolate the UPS mainframe for inspection without cutting off load power, completely avoiding economic losses from maintenance shutdown. Supported by complete safety protections and standard CE/IEC/ISO certifications, this series is a high cost-performance power solution for all harsh unattended outdoor working conditions.

5 Core Selling Points

  1. IP55 sealed cabinet with built-in air conditioner, all-weather outdoor deployment without equipment room
  2. Online double conversion, zero transfer time & pure sine wave for stable power supply
  3. Dual-stage intelligent charging system to prolong battery life and reduce maintenance cost
  4. Optional harmonic filter + SCR backfeed protection, high grid adaptability & full safety guarantee
  5. Independent maintenance bypass, zero downtime overhaul for continuous load power

System Layout Diagram:

System Layout Diagram1

Product service:

1. Pre-sales consultation; After-sales worry-free.

2. Support ODM and OEM.

3. Online guidance and Technical support.

Technical Parameters

Model CNW330-10K CNW330-15K CNW330-20K CNW330-30K CNW330-40KVA
Capacity 10KVA 15KVA 20KVA 30KVA 40KVA
System parameters
Relationship between output power factor cosφ and the load
0.5~0.8 inductive load 100%
0.8~1.0 inductive load 100~80%
1.0 linear Load 80%
0.8~1.0 capacitive load 80%
0.5~0.8 capacitive load 70%
Computer load 80%
Overall efficiency (normal mode) Load 100% 92%
50% load 90%
Overall efficiency (economic model):100% load 98%
Max leakage current(mA) 100
Standby economy mode Standard function
Mean time between failures(MTBF): 200,000 hours
Computer monitoring port Standard configuration RS232, RS485 / MODBUS
Operating temperature -10° ~ 50 °C
Max relative humidity 95 % (non-condensing)
Cooling Forced ventilation (fan speed varies with load and temperature)
Maximum altitude Rated power at 1000m (increase by 100m and decrease by -1%), maximum 4000m
Noise (dB) 52 ~ 58
Protection class(EN 60529) IP55
Incoming and outgoing line method Bottom/Back
Safety standard Safety regulations:GB4943  ,EN 50091-1;EMC:GB7260.2,GB/T 17626.2~5EMC, EN 50091-2
Physical parameters
Width (mm) W 900 1060
Depth * Height (mm) 1200*1950 1295*1950
Weight ( Kg)(Battery not included) 273 299 311 454 602
Rectifier input
Rated voltage 208VAC Three phase three wire
Voltage range ± 10 %  (± 20 % adjustable)
Rated frequency 50/60Hz  Automatic identification
Frequency range 45 ~ 65
Input power soft start function Yes, 0-100%,10-300 seconds settable
Input power factor  cosφ Up to 0.99 (with harmonic filter)
Input current harmonic component(THDI ) Minimum<5% (with harmonic filter)
Max. input current [A] 33 49 66 99 133
Rectifier output
Maintenance voltage (20°C) Battery type1 and 2 :V = (2.266 * el.) Vdc
Battery type 3  :V = (2.21 * el.) Vdc
Battery type 0:The voltage value is between type 1 and 2, and the voltage value adjustment range V =(2.09~2.4) * el. [Vdc]
Battery type1 and 2 :V(%Recharging<95%)= (2.32 * el.) Vdc
Battery type 3  :V(%Recharging<95%)= (2.4 * el.) Vdc
Charging Voltage (20°C) Battery type 0:The voltage value is between type 1 and 2, and the voltage value adjustment range V =(2.09~2.4) * el. [Vdc]
Max charging Voltage (2.32 * el.) Vdc
Charger output voltage stabilization accuracy 1%
DC ripple voltage component ≤1%
Battery
Number of units (rated voltage) 16 units(192VDC)
Charging current setting 0.1A x C10
Battery discharge termination voltage Battery 1, 2 and 3:No-load discharge current,Vmin=(1.81 * el.) [Vdc]
Battery 1, 2 and 3:output current=Ah Capacity,Vmin=(1.65 * el.) [Vdc]
Battery 1, 2 and 3:output current>Ah Capacity,Vmin=(1.60 * el.) [Vdc]
Battery 0 type: Factory default values ,Vmin=(1.67 * el.) [Vdc]
Adjustment range Vmin =(1.57~1.88)*el. [Vdc]
Three-phase inverter output
Rated capacity [KVA] 10 15 20 30 40
Rated power[KW] 8 12 16 24 32
Rated voltage [V] 208VAC  Three-phase four-wire
Rated current [A] 22 33 44 66 88
Phase voltage setting 112~ 135 V (control panel )
Peak factor(Ipeak/Irms) 3:01
Wave form Sine wave
Voltage phase shift (degrees) 100% balanced load ± 1′
Voltage phase shift (degrees) 100% unbalanced load ± 2′
Phase voltage difference 100% balanced load ± 1 %
Phase voltage difference 100% unbalanced load ± 3 %
Total harmonic content(THDv)100%linear Load <2%
Total harmonic content(THDv)100% non-linear Load <5%
Steady voltage stability ± 1 %
Transient voltage response ± 5 % within 10ms
Rated frequency same as input
Frequency stability ± 0.5% when asynchronous; During synchronization, ± 2% (can be set to ± 1-5%, operated by the panel)
Overload 600’ / 10’ / 1’  (110/125/150% Rated current)
Short circuit for 0.1 seconds 2 times input
Inverter efficiency(100% load) 90%
Three phase bypass input
Rated capacity [KVA] 10 15 20 30 40
Rated voltage [V] 208VAC  Three-phase four-wire
Input voltage range ±15 %(Can be adjusted from the control panel to± 10 %,± 20%)
Rated frequency [Hz] 50 / 60
Voltage range ±2 %(Can be adjusted from the control panel to± 5 %)
“STAND-BY ON”  (Switching time from bypass to inverter in economic mode) 2~5ms
Inverter/bypass switchover time <1ms
Overload capacity 10’/1’/18”(150/175/200% Rated current)
Standard configuration Feed current protection
Port Project in Panama

Port Project in Panama

What application scenarios is CNW330 mainly suitable for?
It is customized for unattended outdoor sites: telecommunication base stations, road & tunnel monitoring, oil & gas fields, photovoltaic/wind power measuring equipment, water conservancy pumping stations and remote industrial control cabinets.
What is the function of the SWMB maintenance bypass switch?
After closing SWMB and disconnecting SWIN, SWBY and SWOUT, the UPS host can be fully isolated for overhaul. The load keeps powered without interruption, avoiding economic losses caused by shutdown maintenance. Note that neutral line cannot be isolated on three-phase output models.
What is the operating temperature range of CNW330?
With supporting cabinet air conditioner, the applicable ambient temperature covers -30℃ ~ +50℃, adapting to high-temperature, cold, rainy and dusty field environments.
Is the harmonic reduction filter standard configuration?
No, it is an optional accessory. Installed at the front of rectifier, it suppresses input current harmonic distortion to improve power grid compatibility and power quality, protected by built-in fuse.

Related products

12
CNS-L1208 Series 12V Lithium lon Iron Phosphate Battery(LiFePO4)
3
CNS-LFP12V Series Lead Acid Replacement Battery ( LiFePO4 )
2
CNS-LFP24V Series Lead Acid Replacement Battery ( LiFePO4 )
2
CNS-LFP36V Series Lead Acid Replacement Battery ( LiFePO4 )

Related Articles

-2023
Shenzhen CONSNANT Technology Co., Ltd. team building activities Huizhou trip.
-12025
CONSNANT 10th Anniversary Celebration
-2024
CONSNANT Team Building & Annual Meeting Activities

Contact us

Partner with CONSNANT to find the perfect power system for your business. Our technical team is ready to provide customized solutions to optimize power usage and maximize efficiency.

Solution5 1