products

Three-Phase Autotransformer

Three‑Phase Autotransformer 10KVA‑1000KVA

share

Facebook
LinkedIn

Nominal Capacity: 10-1000KVA

Input/Output Voltage Range: 200V/220V/380V/400V/415V/440V/480V  (line-line)or  customized

Nominal Frequency: 50/60HZ

Description

This series three‑phase autotransformer covers power capacity from 10KVA (8KW) to 1000KVA (800KW), compatible with 50Hz / 60Hz global power grids. Adopting Baosteel B50A470 silicon steel sheet for core material, it features precise voltage regulation of ±1%, low noise performance and flexible IP protection grades. Designed for heavy‑duty industrial environments, it delivers reliable voltage adjustment and power conversion for CNC machine tools, steel plants, mine auxiliary power distribution and factory workshops.

Main Application Scenarios

  • CNC Machine Tool: Stabilizes input voltage for precision CNC processing equipment, avoids voltage deviation affecting machining accuracy.
  • Steel Plant: Suits heavy‑load working conditions of steel production lines, provides stable power adjustment for industrial production equipment.
  • Mine Auxiliary Power Distribution: Matches auxiliary power supply requirements for mining sites, adapts complex and volatile on‑grid power conditions.
  • Factory Workshop: General‑purpose voltage transformation & regulation for workshop production machinery and complete production lines.

Key Technical Parameters

  1. Power Rating: 10KVA/8KW ~ 1000KVA/800KW
  2. Phase Configuration: 3Phase+Neutral+Ground / 3Phase+Ground
  3. Operating Frequency: 50Hz / 60Hz dual‑frequency compatibility
  4. Voltage Regulation Accuracy: ±1%
  5. Impedance Voltage: 4%
  6. Core Material: Baosteel B50A470 silicon steel sheet
  7. Protection Grade: Standard IP21; IP54, IP65 available for outdoor customized requirements
  8. Noise Level: 50dB‑59dB@100% load (measured at 1‑meter distance)

Product Advantages

  • Precise Voltage Regulation: ±1% voltage regulation accuracy, effectively stabilizes fluctuating grid voltage to safeguard precision industrial equipment.
  • High‑Quality Core Material: Adopts Baosteel B50A470 silicon steel sheet, lowers core loss, improves transformer efficiency and service life.
  • Flexible Protection Options: Standard IP21 for indoor workshop use; IP54 / IP65 customizable for dust‑proof and water‑proof outdoor working conditions.
  • Dual‑Frequency Compatibility: Supports 50Hz & 60Hz, applicable for domestic and overseas industrial projects.
  • Wide Industrial Application Range: Perfect for CNC machine tools, steel plants, mine power distribution and general factory workshops.
  • Controllable Low‑Noise Performance: Optimized structure design, noise within 50‑59dB at full load (1‑meter test point), suitable for long‑time factory operation.

Technical Parameters

Three  Phase  Autotransformer
Model 1KVA to 1000KVA
Capacity 10KVA/8KW~1000KVA/800KW
Input/Output
Phase 3Phase+Neutral+Ground/3Phase+Ground
Voltage Range 200V/220V/380V/400V/415V/440V/480V  (line-line)or  customized
Frequency  Range 50Hz/60Hz
Power Factor >80%/0.85
Input
Waveform Distortion No distortion (the same with input waveform)
THDi THDi<3%@100%linear load
Output
Voltage Regulation ±1%
Efficiency >98%on  full  load
THDu THDu<1%(linear  load)
Overload Capability 300%for 10 seconds,150%for 120 seconds
Insulation Resistance >100MΩ/DC500V
Short Circuit Impedance 4%
System
Material Transformer coil adopts 200 degree high temperature wire,silicon steel sheet using Baosteel-B50A470 materia
Connection Mode Yn11
Insulation Class H class (200 degree C)
Insulated Strength >2500V/Min
IP Class IP21(or IP54,IP65 customized for outdoor)
Working Temperature Below20℃~50℃
Relative Humidity 0-95%(non-condensing)
Cooling  Method Natural cooling/Fan system cooling
Display Type LED display or digital display (option)
Dispaly Show Input voltage,output voltage,working  indicator light
Noise
59db@100%load 50db@100%load,(1 meter away)
40db@70%load 45db@70%load,(1 meter away)
What phase connection types are available?
Two connection options: 3Phase+Neutral+Ground and 3Phase+Ground for different site wiring requirements.
What is the voltage regulation precision?
Voltage regulation accuracy reaches ±1%, ensuring stable output voltage even with input grid fluctuation.
Can I get higher IP grade for outdoor installation?
Standard protection grade is IP21 for indoor use. IP54 and IP65 are available upon custom request for outdoor harsh environments.
How much noise will be generated under full‑load operation?
Noise level is 50dB‑59dB when operating at 100% load, measured at a distance of 1 meter from the unit.

Related products

Three‑Phase Isolation Transformer 3KVA‑3000KVAThree‑Phase Isolation Transformer 3KVA‑3000KVA
Three‑Phase Isolation Transformer 3KVA‑3000KVA
Three-Phase Autotransformer
Three‑Phase Autotransformer 10KVA‑1000KVA
Single‑Phase Transformer 1KVA‑200KVA
Single‑Phase Transformer 1KVA‑200KVA
512V 100Ah High-Voltage LiFePO4 Battery System
CNLP512100-H 512V 100A High Voltage Lithium Battery System Backup Power

Related Articles

48V DC Telecom Power System vs Outdoor UPS Which Backup Architecture Fits a Remote
48V DC Telecom Power System vs Outdoor UPS: Which Backup Architecture Fits a Remote Site?
CONSNANT Industrial UPS Load Schedule Review
How to Choose an Industrial UPS for a Manufacturing Plant
CONSNANT Petrochemical Project Industrial UPS Installation
Industrial UPS for Oil & Gas Projects: What Should Buyers Specify?
CONSNANT Industrial UPS Main and Bypass Cabinets
Industrial UPS Maintenance Bypass: When Should a Project Specify a Separate Bypass Cabinet?

Contact us

Partner with CONSNANT to find the perfect power system for your business. Our technical team is ready to provide customized solutions to optimize power usage and maximize efficiency.