products

-3 -4 -5

CNW110L-1K Series 1KVA/800W Pole/Wall Mounted Outdoor UPS With Lithium Battery

share

Facebook
LinkedIn

Model: CNW110L-1K

Nominal Voltage: 240VAC

Nominal Frequency: 50/60HZ

Installation Method: Pole-Mounted / Wall-Mounted

 

Application field:

  • CCTV
  • Traffic Lights
  • Road Monitors
  • Telecom

Description

The CNW110L-1K is a 1KVA/800W pole/wall-mount outdoor UPS built with lithium battery. It is specially designed for municipal traffic, security monitoring, and communication outdoor projects, perfectly suited for unattended field power supply scenarios.
Features:
  • Core Performance

Adopting double-conversion online technology, this UPS delivers pure sine wave output with constant voltage and constant frequency. It provides zero-interruption power supply and stable low-noise operation even under severe grid fluctuation. Equipped with an intelligent microprocessor control system and built-in boost-buck AVR automatic voltage regulation, it supports wide-range voltage input and auto-restart after AC power recovery. The high-efficiency smart charger greatly shortens battery charging time and improves standby efficiency.

  • Full Outdoor Protection

The integrated cabinet features excellent heat insulation, dustproof, damp-proof and waterproof performance to adapt to harsh outdoor environments. Built-in lightning protection effectively resists lightning strikes and surge damage. A standard network monitoring card supports real-time remote monitoring and remote maintenance, reducing on-site operation costs.

  • User-Friendly Structure Design

Featured with a single-door design, the unit allows full operation and maintenance from the front side. The internal double-layer layout separates the lithium battery compartment and lightning protection & distribution components. The UPS main module is door-hung, and the drawer-type control unit enables fast and easy installation, replacement and maintenance, especially for pole-mounted high-altitude scenarios.

  • Application Scenarios

Ideal for outdoor surveillance cameras, roadside equipment, communication base stations, municipal security facilities and other outdoor low-power devices requiring reliable uninterrupted power supply.

 

Product Structure Diagram

Pole/Wall-Mounted Outdoor UPS

Pole/Wall-Mounted Outdoor UPS

  • Theoutdoor UPS system has good protection function: such as heat insulation, dustproof, damp proof, waterproof etc.
  • Doubleconversion on line technology, which enables the UPS to provide a pure sine wave voltage, with constant frequency, constant voltage, low noise and no interruption, no matter the utility power fluctuation. It protects the user’s equipment ideally all the time.
  • Thesystem has one door; you can open the front door to operate the system. There are two layers inside the system, the first layer is used to hold batteries;The second floor installation lightning protection device, power distribution equipment etc. The UPS module is hanged on the door.

 

UPS Module Introduction

Outdoor UPS module

  • ThisUPSis a precision piece of equipment with 16 bit microprocessor and advanced software programming technology. High frequency SPWM is created to control the inverter of UPS. The simplified control circuit, enhances the stability of UPS and real-time performance. That makes UPS respond the variety of external environment rapidly and ensures the control is compact and reliable.
  • Advancedvoltage compensation technique, makes the input voltage range from 115VAC to 295VAC, using batteries less, enhancing the adaptability against the bad power condition.
  • Advancedwide input frequency technique, makes the input frequency range from 45Hz to 55Hz, compatible with generator under variable circumstance.
  • Theadvanced PFC technology, improves the input power factor close to utility, raises the power efficiency, removes the harmonic noise from UPS to utility, lowers UPS operational cost, it’s really a good environmental protection power supply.
  • Standardbypass function, when the UPS faults, it can transfer to bypass mode and provide alarm signal.
  • Smartmanagement function. If main power blackout, ups will transfer to backup mode to supply loads. When battery voltage is low, ups would protect itself and shuts down. When the main power recovers, the UPS would check the main power itself, if the main power is also normal, ups would turn on automatically to supply loads; if main power is abnormal, UPS would just turn on charger to charge the battery until the main power is normal.
  • DCstart function, when there is no main power; UPS can be turned on by battery, to meet the user’s emergency needs. The cold start function is quite strong. UPS can be cold started on full load situation.

Product service:

1. Pre-sales consultation; After-sales worry-free.

2. Support ODM and OEM.

3. Online guidance and Technical support.

Technical Parameters  

Model  CNW110L-1K
Capacity 1kVA/0.8kW
Input
Nominal Voltage 220/230/240VAC, L+N+PE
Voltage Range 100-300VAC
Frequency 40-70Hz
Power Factor >0.99
THDi ≤4% (linear load); ≤5% (non-linear load)
Output
Nominal Voltage 220/230/240VAC, L+N+PE
Voltage Regulation ±1%
Frequency 50/60Hz±0.1%
Crest Ratio 3:1
THDu ≤2% (linear load); ≤5%(non-linear load)
Transfer Time Line mode to battery mode,0ms; inverter to bypass ,4ms (typical)
Waveform Pure sine wave
Overload Time Line mode:                 Battery mode:

30min@102%-110% load        1min@102%-110% load

10 min@110-130% load          10s@110-130% load

30s@130%-150% load           3s@130%-150% load

200ms@>150% load           200ms@>150% load

Efficiency
Line Mode 94.5%
Battery Mode 88.5%(36VDC)
ECO Mode 98%
Battery
Type Lithium-ion battery
Voltage 36VDC
Battery Number 12.8VDC 8Ah*3pcs
Charging Current 4A
Charging Mode Two/Three-period charging
Management
Intelligent Port RS232/USB port/SNMP card (optional)/Dry contact kit (optional)
Environment
Operation Temperature 0-55℃
Relative Humidity 0-95%(non-condensing)
Noise <50dB@1 meter
Altitude Up to1000m without derating
What installation methods does this UPS support? Can it be used outdoors?
It supports wall-mounted and pole-mounted installation. Designed specifically for outdoor applications, the unit features waterproof, dustproof, damp-proof, heat insulation and lightning protection, suitable for unattended outdoor environments.
What is the rated power? What loads is it suitable for?
Rated at 1KVA/800W. It is ideal for outdoor cameras, municipal traffic equipment, small communication base stations and other low-power outdoor devices.
What working mode does it adopt? Does grid fluctuation affect operation?
It adopts online double-conversion mode with boost/buck AVR voltage stabilization. It outputs pure stable sine wave under severe grid fluctuation, ensuring zero power interruption and full load protection.
Is the equipment easy to maintain?
Front single-door design with drawer-type control unit and door-hung UPS module. The internal double-layer structure makes installation and maintenance fast and convenient, especially for high-altitude pole installation scenarios.

Related products

12
CNS-L1208 Series 12V Lithium lon Iron Phosphate Battery(LiFePO4)
3
CNS-LFP12V Series Lead Acid Replacement Battery ( LiFePO4 )
2
CNS-LFP24V Series Lead Acid Replacement Battery ( LiFePO4 )
2
CNS-LFP36V Series Lead Acid Replacement Battery ( LiFePO4 )