products

-2 -3 -12 -111 2 2

CNH330 Series 10-160KVA 3Ph Tower High Frequency Online UPS

share

Facebook
LinkedIn

Model Number: CNH330 10 – 160KVA

Nominal Capacity: 10-160KW

Nominal Voltage: 380/400/415VAC

Input Voltage Range: 305 ~ 478VAC; 208 ~ 304VAC(output derated below 70%)

Nominal Frequency: 50/60HZ

 

Application:

  1. Data centers, server rooms and IDC clusters
  2. Medical imaging equipment, operating rooms and vital monitoring systems in hospitals
  3. Bank clearing centers, securities computer rooms and government information rooms
  4. Industrial automation production lines, PLC control systems and precision CNC equipment
  5. Communication core rooms, metro signal systems and base stations
  6. Laboratory precision instruments, security monitoring and fire linkage systems

3P/3P 400V High Frequency Online UPS 10-100KVA

The CNH330 series is a 3P/3P three-input three-output tower high-frequency double-conversion online UPS developed by CONSNANT. Its power range covers 10kVA to 160kVA. Adopting silicon carbide power devices and dual DSP+MCU control architecture with an output power factor of 1.0, the product delivers clean, uninterrupted power protection for critical loads such as data centers, medical facilities, industrial automation, finance and communication systems. It fully isolates grid disturbances including voltage sags, surges, harmonics and frequency deviations, with zero-break switching between mains and battery modes to guarantee 24/7 stable operation of core equipment.

Feature & Advantages:

  • Integrated Solution for Data Center
    UPS can be integrated with battery cabinet,PDU external maintenance bypass, offering excellent choice for data center.
  • 3Phase In/3Phase Out UPS
    It is 3Phase In/3Phase Out high-density UPS system, of which input current is kept in balance, No unbalance problem might occur.
  • Digital Control
    This series UPS is controlled by digital signal processor(DSP);enhance it increases reliability, performance, self-protection, and self-diagnostics and so on.
  • Battery Configurable
    The battery voltage of this series UPS can be configured at30 blocks,32 blocks, 34 blocks, 36 blocks,38 blocks, 40 blocks,42 blocks, 44 blocks, 46 blocks, 48 blocks or 50 blocks according to your convenience.
  • EPO Function
    The series UPS may be completely shut off when the EPO ispressed.REPO function(Remote EPO) is also available in thisseries UPS.
  • Intelligent Charging Method
    The series UPS adopts advanced three-stage charging method:

    • 1st stage: high current constant charging to guarantee to charge back to 90%;
    • 2nd stage: Constant voltage in order to bitalize battery and make sure batteriesare fully charged;
    • 3rd stage: floating mode. with this 3-stage charging method, it extends the life of the batteries and guarantees fast charging.
  • LCD Display
    With LCD displays, the user may easily get UPS Status and its operationalparameters, such as input/output voltage, frequency & load%, banttery %
    and ambient termperature, etc…
  • Intelligent Monitoring Function
    Via optional SNMP Card, you may remotely control and monitor the UPS.
  • Charging Current is Configurable
    Via setting tool, the user may set the capacity of the batteries aswell as reasonable charging current as well as maximum charging current. Constantvoltage mode, constant current mode or floating mode can be switchedautomatically and smoothly.

Technical Parameters

Model CNH330 10KVA CNH330 60KVA CNH330 80KVA CNH330 100KVA CNH330 120KVA CNH330 160KVA
Capacity 10-40KVA 60KVA 80KVA 100KVA 120KVA 160KVA
Input
Nominal Voltage 380/400/415 Vac(3Ph+N+PE)
Operating Voltage Range 138~485Vac
Operating Frequency Range 40Hz-70Hz
Power Factor ≥0.99
Harmonic Distortion (THDi) ≤3%(100%non-linear load)
Harmonic Distortion (THDi) 220Vac Max.Voltage:+25%(optional+10%,+15%,+20%).  230Vac.Max:+20%(optional+10%,+15%)
240Vac Mac.Voltage:+15%(optional+10%)               Min.Voltage:-45%(optional-20%,-30%)
Frequency synchronize tracing range:±10%
Generator Input Support
Output
Output Voltage 380/400/415Vac(3Ph+N+PE)
Voltage Regulation ±1%
Power Factor 0.9
Output Frequency 1.Line Mode:synchronize with input;when input frequency>±10%(±1%/±2%/±4%/±5%optional)
2.Battery Mode:50/60*(1±0.02%)Hz
Crest Factor 3:1
Harmonic Distortion (THD) ≤2%with linear load ≤4%with non linear load
Efficiency 95%
Battery
Battery Voltage Optional Voltage:±180V/±192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/300Vdc
(30/32/34/36/38/40/42/44/46/48/50 pcs optional)
Charge Current(A)(charge current
can be set according to battery
capacity installed)
10-20k Max 5A
30-40k Max 10A
Max.15A Max.20A    Max.30A MaX.45A
System 
Transfer Time Utility to battery:Oms;Utility to bypass:Oms
Overload Load≥110%:last 60min,≤125%:last 10min,≤150%:last 1min
Alarm Overload,utility abnormal,UPS fault,battery low,etc
Backfeed Support
Protection Short circuit,overload,over temperature,battery low,fan fault alarm
Communication USB,RS232,RS485,Parllel port,REPO port,LBS port,Backfeed port,Intelligent slot,SNMP card (optional),Relay card(optional)
Environmental
Operating Temperature 0℃~40℃
Strorage Temperature -25℃~55℃(no battery)
Humidity 0~95%(non condensing)
Altitude <1500m.When>1500mm,lower the rated power for use
Noise Level <58dB <60dB <62dB <63dB <65dB <66dB
Physical
Dimensions H/S D*W*H(mm) 720*250*535 865*250*862                   885*440*1200
Net Weights(kg) 10K:33/15K:33.5
20K:34/30K:35
40K:40
70.5 150 162 196
Standards
Safety IEC/EN62040-1,IEC/EN60950-1
What power ratings does the CNH330 series cover?
The series fully covers 10/15/20/30/40/60/80/100kVA three-phase tower UPS. All models adopt unified DSP+MCU dual control architecture and online double conversion topology. High-power cabinets share the same appearance size, while small-power models have compact cabinet dimensions with consistent core control logic.
How many units can be paralleled at maximum? Can multiple machines share one battery pack?
Max 6 units parallel connection, supporting N+1 redundant backup or capacity expansion. All parallel UPS can share one external battery group, eliminating separate battery cabinets for each unit and reducing space and battery cost.
Will parallel units conflict when mains recovers?
Equipped with Power walk-in soft start function. Users can set delay startup time via touch screen to stagger power restoration of each UPS, effectively lowering surge impact on generators and front-end power distribution.
What optional communication and expansion modules are available?
Dual mains input module, programmable 4-channel dry contact relay card, battery temperature compensation module, SNMP network monitoring card, matched external battery cabinet.

Related products

12
CNS-L1208 Series 12V Lithium lon Iron Phosphate Battery(LiFePO4)
3
CNS-LFP12V Series Lead Acid Replacement Battery ( LiFePO4 )
2
CNS-LFP24V Series Lead Acid Replacement Battery ( LiFePO4 )
2
CNS-LFP36V Series Lead Acid Replacement Battery ( LiFePO4 )

Related Articles

-2023
Shenzhen CONSNANT Technology Co., Ltd. team building activities Huizhou trip.
-12025
CONSNANT 10th Anniversary Celebration
-2024
CONSNANT Team Building & Annual Meeting Activities

Contact us

Partner with CONSNANT to find the perfect power system for your business. Our technical team is ready to provide customized solutions to optimize power usage and maximize efficiency.

Solution5 1