Model Number: CNH330 10 – 160KVA
Nominal Capacity: 10-160KW
Nominal Voltage: 380/400/415VAC
Input Voltage Range: 305 ~ 478VAC; 208 ~ 304VAC(output derated below 70%)
Nominal Frequency: 50/60HZ
3P/3P 400V High Frequency Online UPS 10-100KVA
The CNH330 series is a 3P/3P three-input three-output tower high-frequency double-conversion online UPS developed by CONSNANT. Its power range covers 10kVA to 160kVA. Adopting silicon carbide power devices and dual DSP+MCU control architecture with an output power factor of 1.0, the product delivers clean, uninterrupted power protection for critical loads such as data centers, medical facilities, industrial automation, finance and communication systems. It fully isolates grid disturbances including voltage sags, surges, harmonics and frequency deviations, with zero-break switching between mains and battery modes to guarantee 24/7 stable operation of core equipment.
Feature & Advantages:
Technical Parameters
| Model | CNH330 10KVA | CNH330 60KVA | CNH330 80KVA | CNH330 100KVA | CNH330 120KVA | CNH330 160KVA |
| Capacity | 10-40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 160KVA |
| Input | ||||||
| Nominal Voltage | 380/400/415 Vac(3Ph+N+PE) | |||||
| Operating Voltage Range | 138~485Vac | |||||
| Operating Frequency Range | 40Hz-70Hz | |||||
| Power Factor | ≥0.99 | |||||
| Harmonic Distortion (THDi) | ≤3%(100%non-linear load) | |||||
| Harmonic Distortion (THDi) | 220Vac Max.Voltage:+25%(optional+10%,+15%,+20%). 230Vac.Max:+20%(optional+10%,+15%) 240Vac Mac.Voltage:+15%(optional+10%) Min.Voltage:-45%(optional-20%,-30%) Frequency synchronize tracing range:±10% |
|||||
| Generator Input | Support | |||||
| Output | ||||||
| Output Voltage | 380/400/415Vac(3Ph+N+PE) | |||||
| Voltage Regulation | ±1% | |||||
| Power Factor | 0.9 | |||||
| Output Frequency | 1.Line Mode:synchronize with input;when input frequency>±10%(±1%/±2%/±4%/±5%optional) 2.Battery Mode:50/60*(1±0.02%)Hz |
|||||
| Crest Factor | 3:1 | |||||
| Harmonic Distortion (THD) | ≤2%with linear load ≤4%with non linear load | |||||
| Efficiency | 95% | |||||
| Battery | ||||||
| Battery Voltage | Optional Voltage:±180V/±192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/300Vdc (30/32/34/36/38/40/42/44/46/48/50 pcs optional) |
|||||
| Charge Current(A)(charge current can be set according to battery capacity installed) |
10-20k Max 5A 30-40k Max 10A |
Max.15A | Max.20A | Max.30A | MaX.45A | |
| System | ||||||
| Transfer Time | Utility to battery:Oms;Utility to bypass:Oms | |||||
| Overload | Load≥110%:last 60min,≤125%:last 10min,≤150%:last 1min | |||||
| Alarm | Overload,utility abnormal,UPS fault,battery low,etc | |||||
| Backfeed | Support | |||||
| Protection | Short circuit,overload,over temperature,battery low,fan fault alarm | |||||
| Communication | USB,RS232,RS485,Parllel port,REPO port,LBS port,Backfeed port,Intelligent slot,SNMP card (optional),Relay card(optional) | |||||
| Environmental | ||||||
| Operating Temperature | 0℃~40℃ | |||||
| Strorage Temperature | -25℃~55℃(no battery) | |||||
| Humidity | 0~95%(non condensing) | |||||
| Altitude | <1500m.When>1500mm,lower the rated power for use | |||||
| Noise Level | <58dB | <60dB | <62dB | <63dB | <65dB | <66dB |
| Physical | ||||||
| Dimensions H/S D*W*H(mm) | 720*250*535 | 865*250*862 | 885*440*1200 | |||
| Net Weights(kg) | 10K:33/15K:33.5 20K:34/30K:35 40K:40 |
70.5 | 150 | 162 | 196 | |
| Standards | ||||||
| Safety | IEC/EN62040-1,IEC/EN60950-1 | |||||
Partner with CONSNANT to find the perfect power system for your business. Our technical team is ready to provide customized solutions to optimize power usage and maximize efficiency.