Three Phase Output Industrial Online UPS 160 300KVA

CNI330 Series 10-300KVA 3Ph Industrial Online UPS

share

Facebook
LinkedIn

Model Number: CNI330 10-300KVA
Nominal Capacity: 10 – 300KVA
Nominal Voltage: 380/400/415VAC
Maximum Input Voltage Range: +-20%
Nominal Frequency: 50/60HZ

 

Typical Application Scenarios:

  • Power Industry: Power plant DCS control systems, boiler safety monitoring, steam turbine inspection, generator bypass automatic protection devices
  • Petrochemical & Energy: Onshore/offshore oil & gas exploitation, pipeline transmission, chemical production lines, plastic processing equipment
  • Manufacturing: Automated production lines, precision lab testing instruments, metallurgy & mining control systems
  • Other Critical Sectors: Rail transit, tunnel monitoring, water treatment, offshore platforms, emergency safety equipment

Description

CNI330 Series Industrial UPS are fully customized integrated power supply systems designed for harsh industrial operating conditions, whose core R&D and design objective is to deliver full-range power protection for critical process loads at industrial sites. Industrial distribution grids commonly suffer from deteriorated power quality, which readily generates various transient voltage disturbances. Such voltage transients can cause irreversible electrical damage to both the internal power modules of UPS units and high-precision critical downstream loads. Industrial UPS are power conditioning equipment specially developed to address these pain points in industrial working conditions.

The CNI330 Series is a 3-phase input & 3-phase output double-conversion industrial online UPS developed by CONSNANT, covering power ratings from 10kVA to 300kVA. It is engineered for harsh industrial environments, available in IP42 and IP54 enclosure protection grades. Standard configuration includes main UPS cabinet plus independent bypass cabinet, with full customization support.
Adopting full-digital high-speed DSP control and pure double-conversion topology, the unit realizes complete electrical isolation between input and output. It effectively handles industrial grid interference such as voltage swings, harmonics and motor inrush current, delivering stable, clean uninterrupted power to critical control equipment, avoiding production shutdown, monitoring system failure and equipment damage caused by blackouts, voltage dips, surges and distortion.

 

Key features:
• Adopt full digital control technology.
• Intelligent detection and monitoring function.
• Digitally control the static switch with zero switch.
• Full isolation between input and output.
• Super low output zero earth voltage.
• DC UPS isolated with utility power completely.
• Cubical design with power standard (customization).
• Multifunctional protection for over-voltage, under voltage, over current, short circuit and over temperature and so on.
• Large-screen LCD monitor with Chinese and English operation interface.
• Ultra-long 256 event record, user-friendly analysis and management to the situation of the power supply (touch screen display).
• Static bypass has a strong anti-overload capability.

 

Product advantages:

Adopting High-speed DSP Control

Adopting voltage and current stepping technology under CPU control, the rectifier of UPS has a soft start function. The input step is less than 15 seconds (adjustable), and the maximum impact current on the power grid does not exceed the rated current.

High Reliability

Built-in input transformer, output transformer, and bypass transformer realize complete Galvanic isolation. Instead of discrete IGBT and SCR components, we uses Modular IGBT and SCR in Rectifier and Inverter, bringing in extremely high reliability.

Advanced BMS

Intelligent battery management, comprehensive charge and discharge management of batteries, including charging voltage and current limiting, discharge cut-off voltage, extending battery lifetime 30%-50%.

Flexible customization

Industrial UPS can be customized according to the customer’s environment, including input and output voltage, phase, frequency, battery voltage, charging current and IP level of the cabinet, etc.

Integrated design

The entire machine adopts a less fuse design, using circuit breakers, contactors, and electronic static switches. The circuit protection technology is advanced, greatly improving the reliability of the entire machine.

Strong Impact Ability

Adopting pulse-by-pulse technology to ensure that the maximum short-circuit current does not exceed the allowable range of single pulse short time IGBT, a pulse-by-pulse current limiting scheme is adopted.

Suitable for harsh environments

It can be applied in harsh environmental conditions such as dust, pests, high-temperature conditions, and earthquake areas to protect your important production processes and systems.

Parallel operation

Advanced distributed active parallel technology can realize parallel operation of 6PCS UPS units without the need for centralized bypass cabinet.

High compatibility

Compatible with Lead Acid (vented/sealed), NiCd (vented/gas recombination) batteries and lithium batteries.

 

Product service:
1. Pre-sales consultation; After-sales worry-free.
2. Support ODM and OEM.
3. Online guidance and Technical support.

 

Technical Parameters:

Model CNI330 10-300KVA
Rating(kVA)*@P.F.0.8 vs DC Rated Voltage
Nominal Power(kW) 8 12 16 24 32 40 48 64 80 96 128 160 240
110Vdc 10 15 20 30 – – – – – – – –
220Vdc 10 15 20 30 40 50 60 80 100 120 – – –
384Vdc 10 15 20 30 40 50 60 80 100 120 160 200 300
Input
Input Voltage 380/400/415 Vac 3Phase±20%,50/60Hz±10%
Power Factor Up to 0.95,if increase harmonic filter can reach to 0.99
Input THDi <10%@rated load,if increase harmonic filter can<5%
Bypass Input Voltage 380/400/415 Vac 3Phase±25%,50/60Hz±15%
Battery
DC Voltage 110/220/384VDC  (Optional)
Battery Type Lead-acid,Ni-cd or Li-lon
Output
Nominal Voltage 380/400/415 Vac 3-phase
Frequency 50/60Hz(Adaptive),±0.05%Hz synchronization,±2Hz asynchronous
Voltage Regulation ±1%static;±5%dynamic;8%load change,<10 ms recovery
Overload Capacity 125%for 10 min;150%for 1 min;200%for 100ms
Harmonic Distortion THDv <2%linear load;<5%non-linear load
System
Cooling Forced ventilation and redundant fans
Color RAL 7035(standard),other optional
Protection Degree IP42(standard),other optional
Environmental
Operating Temperature -10℃ to 40℃(up to 55℃ with de-rating)/Storage:-20℃ to 70℃
Altitude <1000m(For places higher than 1000 meters,the output will be -1%of thenominal value for every 100 meters higher)
Audible Noise at 1 Meter(dBA) 65 to 75(Depending on rating and options)
User Interface
Front Panel Graphic display,minic LED panel,Running indicator,EPO optional
Connectivity Includes alarm relay card and RS485 interface
Standards Quality assurance,environment,health and safety:ISO 9001:2008,ISO 14001:2004,
BS OHSAS 18001:2007;Safety:IEC EN 62040-1;EMC:IEC EN 62040-2;
Environmental aspects:IEC EN 62040-4;
Test and performance:IEC EN 62040-3 VFI-SS-111;
Protection degree:IEC 60529;
Marking:CE

UPS Model List:

Model Capacity Nominal Voltage Battery Voltage Power   Factor W×DxH(mm) Weight    (KG)
CNI310 10KVA/8KW 380/400/415VAC 110/220/384VDC 0.8 600x800x1900 (2050) 327
15KVA/12KW 372
20KVA/16KW 418
30KVA/24KW 516
40KVA/32KW 620
60KVA/48KW 220/384VDC 800x800x1900 (2050) 720
80KVA/64KW 920
100KVA/80KW 1200x800x1900 (2050) 1070
CNI330 10KVA/8KW 380/400/415VAC 110/220/384VDC 0.8 600x800x1900 (2050) 300
15KVA/12KW 410
20KVA/16KW 445
30KVA/24KW 536
40KVA/32KW 650
60KVA/48KW 220/384VDC 800×800×1900 (2050) 758
80KVA/64KW 952
100KVA/80KW 1500×800×1900 (2050) 1100
120KVA/96KW 1200
160KVA/128KW 384VDC 1600x800x1900 (2050) 1428
200KVA/160KW 1902
300KVA/240KW 2000×850×1900 (2050) 2500
(PF=0.9 can be for option)
Single Phase Output 60 100KVA Industrial Online UPS (10)

Chemical factory in Kashgar City, Xingjiang

Single Phase Output 60 100KVA Industrial Online UPS (11)

Power Plant in Russia

Single Phase Output 60 100KVA Industrial Online UPS (9)

Shanxi Sinopec

What are the core differences between industrial UPS and standard commercial UPS?
Operating Environment: Industrial UPS adapts to harsh working conditions with dust, humidity, oil mist, wide temperature range, vibration and strong electromagnetic interference, and supports IP42/IP54 high-protection cabinets, while commercial UPS are only applicable to clean, constant-temperature computer rooms. Customization Capacity: CNI330 industrial series supports full-dimensional customization of cabinet, bypass, communication, battery management and parallel system; commercial models are highly standardized with limited modification space. Anti-interference Performance: Industrial units are optimized for grid distortion, voltage transients and motor impulse loads, capable of enduring wide voltage fluctuation and instantaneous high-voltage surges to prevent damage to UPS mainframes and downstream industrial control equipment. Redundancy & Maintenance: Equipped with independent manual bypass cabinet as standard, allowing online maintenance without cutting off power to production loads; most commercial UPS adopt built-in bypass and cannot be maintained under load.
What is the difference between single-phase UPSs vs. three-phase UPSs vs. split-phase UPSs?
Phases of a UPS, such as a single-phase UPS or a three-phase UPS, describe the number of electrical phases that a UPS receives and transmits. Electrical utilities generate three-phase power because that is the most efficient way to transport electricity over long distances. And for larger power consumers, such as large data centers, industrial manufacturing and hospitals, the power stays as three-phase, requiring a three-phase UPS. For smaller power consumers, including residential or office buildings and most K-12 schools, the power is converted to single-phase power. Some applications contain a mix of single-phase and three-phase equipment and require a UPS that can protect both. For those deployments, a split-phase UPS, which can simultaneously provide 120V and 208V output, is often the best option.
Does the CNI330 series support N+X redundant parallel operation? What is the maximum parallel quantity?
Incorporating built-in surge suppression and noise filtering, uninterruptibThe full CNI330 series supports N+X redundant parallel expansion, with a maximum of 8 identical UPS units connected in parallel. The parallel system realizes even load sharing and automatic offline of faulty units. Failure of a single unit will not cut power to downstream critical loads, meeting the 24/7 continuous production requirements of high-reliability industrial scenarios such as petrochemical, power and metallurgy industries. An independent parallel control cabinet can be matched to simplify the joint maintenance of multiple units.
How to configure long backup runtime for industrial UPS?
CNI330 supports external battery cabinets for long backup runtime solutions, configurable from 0.5 hours to 8 hours according to customer demands. The unit is equipped with an intelligent Battery Management System (BMS) to precisely control charging and discharging, prevent overcharge and overdischarge, and extend battery service life by more than 40%. Multiple battery banks can be connected in parallel for high-power models to meet long-duration power outage backup demands.

Related products

Three‑Phase Isolation Transformer 3KVA‑3000KVAThree‑Phase Isolation Transformer 3KVA‑3000KVA
Three‑Phase Isolation Transformer 3KVA‑3000KVA
Three-Phase Autotransformer
Three‑Phase Autotransformer 10KVA‑1000KVA
Single‑Phase Transformer 1KVA‑200KVA
Single‑Phase Transformer 1KVA‑200KVA
512V 100Ah High-Voltage LiFePO4 Battery System
CNLP512100-H 512V 100A High Voltage Lithium Battery System Backup Power

Related Articles

48V DC Telecom Power System vs Outdoor UPS Which Backup Architecture Fits a Remote
48V DC Telecom Power System vs Outdoor UPS: Which Backup Architecture Fits a Remote Site?
CONSNANT Industrial UPS Load Schedule Review
How to Choose an Industrial UPS for a Manufacturing Plant
CONSNANT Petrochemical Project Industrial UPS Installation
Industrial UPS for Oil & Gas Projects: What Should Buyers Specify?
CONSNANT Industrial UPS Main and Bypass Cabinets
Industrial UPS Maintenance Bypass: When Should a Project Specify a Separate Bypass Cabinet?