products

IP56 floor outdoor UPS 1 10KVA with cabinet air conditioner1 IP56 floor outdoor UPS 1 10KVA with cabinet air conditioner2 IP56 floor outdoor UPS 1 10KVA with cabinet air conditioner3 IP56 floor outdoor UPS 1 10KVA with cabinet air conditioner4

CNW110 Series 1-10KVA IP56 Floor Outdoor UPS With Cabinet Air Conditioner

share

Facebook
LinkedIn

Model Number: CNW110 1-10KVA
Nominal Capacity: 1 – 10KVA
Nominal Voltage: 220VAC
Maximum Input Voltage Range: +-20%
Nominal Frequency: 50/60HZ

Application field:
CCTV
Traffic Lights
Telecom

Item No : CNW110 1-10KVA
Order(MOQ) : 10 pcs
Payment : T/T
Product Origin : China
Color : RAL7035
Shipping Port : Shenzhen
Lead Time : 3 weeks
Weight : 85-155 Kg

CNW110 Series 1-10KVA IP56 Floor Outdoor UPS with VRLA/Lithium battery with cabinet air conditioner

Description

The CNW110 series communication side network outdoor UPS is a cost-effective, high-reliability all-in-one power solution specially developed for unattended outdoor microcellular base stations of wireless communication systems, solving core industry pain points including unstable grid power and harsh outdoor operating conditions. Adopting advanced DSP digital control technology and double-conversion online design, the equipment delivers stable and efficient operation with high power conversion efficiency, effectively reducing daily power consumption and long-term operational costs. It supports an ultra-wide input voltage (160V–260V) and frequency adaptation range, which perfectly tolerates severe grid voltage fluctuations and abnormal frequency changes commonly seen in mountainous, remote and suburban areas, ensuring continuous and stable power output for core communication equipment.
Featuring a robust IP55 fully sealed enclosure, this UPS achieves outstanding all-weather weather resistance, adapting to extreme operating temperatures from -40℃ to +50℃. It perfectly resists dust, high humidity, rain erosion and haze corrosion, enabling long-term stable operation in harsh outdoor scenarios such as urban marginal areas, remote roads and mountainous regions. To meet diversified on-site deployment demands, the product supports three flexible installation methods: pole-mounted, wall-mounted and floor-mounted, fitting various complex site conditions. Equipped with a standard 19-inch modular power structure, it supports quick plug-and-play installation and replacement, greatly shortening construction cycles and simplifying daily maintenance. In addition, it is fully compatible with both VRLA batteries and lithium battery packs, providing flexible battery matching and capacity expansion schemes for different project requirements.
In terms of intelligent unattended operation and safety protection, the unit is integrated with comprehensive multi-level protection functions, including overvoltage, undervoltage, overload, short circuit and overheat protection, with built-in lightning surge and insulation protection to eliminate potential safety hazards in humid and thunder-prone outdoor environments. Compatible with SNMP monitoring cards, it supports real-time remote status monitoring, unified platform management and automatic fault alarm, realizing intelligent operation and maintenance. The cabinet reserves independent expansion space for customer equipment and provides multiple cabinet material options to adapt to inland and coastal corrosive environments. Featured with automatic power-on startup after mains recovery, the equipment requires no manual intervention, greatly reducing on-site labor costs and improving unattended operation reliability. With a durable and anti-aging structural design, it lowers equipment replacement frequency and overall project operating expenditure, serving as the ideal high-stability and low-maintenance power supply solution for outdoor communication base stations and edge power scenarios worldwide.

Product service:

1. Pre-sales consultation; After-sales worry-free.

2. Support ODM and OEM.

3. Online guidance and Technical support.

Technical Parameters     

Model CNW110-1KVA CNW110-2KVA CNW110-3KVA CNW110-6KVA CNW110-10KVA
Capacity 1KVA/0.8KW 2KVA/1.6KW 3KVA/2.4KW 6KVA/4.8KW 10KVA/8KW
Nominal voltage 220/230/240VAC
Frequency 50Hz/60Hz
Input
Voltage Range 115-295VAC(±3VAC) 176-297VAC(±3VAC)
Frequency Range 50Hz(46~54Hz); 60Hz(56~64Hz)
Soft Start 0~100%5sec
Power factor 0.98
Output
Voltage Precision 220/230/240VAC x (1±2%)VAC
Frequency Precision 50Hz/60Hz±0.05Hz
Power Factor 0.7/0.8(optional) standard 0.7
Wave Distortion Linear load<3% Non-linear load<6%
Overload capacity Overload(110~150%)for 30 seconds,   then automatically transfer to bypass. When load is normal, it can   automatically transfer to normal mode.
Crest Factor 3:01
Transfer time 0ms(AC to DC)
DC Supply Voltage 48VDC 240VDC 240VDC
Charging current 4A/8A(optional) 4A/8A(optional) 4A/8A(optional) 4.2A 4.2A
Internal Battery Capacity (38/65/80/100AH)optional
Panel display
LED Load level/Battery level, Battery   indicator, Utility power, Inverter, Bypass, Overload, Fault
Communications
Communicate interface RS232, SNMP card (optional)
Work Environment
Temperature -40±℃-55℃
Humidity 0~95%(Non-condensing
Storage Temperature -25℃~55℃
Elevation <1500m
Physical Characteristics
Net Weight(KG) 85 125 125 150 150
Dimension: 613*640*954 650*753*1227 650*753*1227 940*940*1770 940*940*1770
(W x D x H)mm
Projects in Australia

Projects in Australia

China Mobile, China Unicom Project

China Mobile, China Unicom Project

Related products

12
CNS-L1208 Series 12V Lithium lon Iron Phosphate Battery(LiFePO4)
3
CNS-LFP12V Series Lead Acid Replacement Battery ( LiFePO4 )
2
CNS-LFP24V Series Lead Acid Replacement Battery ( LiFePO4 )
2
CNS-LFP36V Series Lead Acid Replacement Battery ( LiFePO4 )

Related Articles

-2023
Shenzhen CONSNANT Technology Co., Ltd. team building activities Huizhou trip.
-12025
CONSNANT 10th Anniversary Celebration
-2024
CONSNANT Team Building & Annual Meeting Activities

Contact us

Partner with CONSNANT to find the perfect power system for your business. Our technical team is ready to provide customized solutions to optimize power usage and maximize efficiency.

Solution5 1