Model: CNW4850L/CNW48100L-6KW
Nominal Capacity: 6KW
Nominal Voltage: 48VDC, 230VAC
Power factor: 1.0
Install Method: Pole Mount, Wall Mount, Floor Installation
Application field:
Traffic Lights
CCTV
Road Monitor Camera
Other outdoor field

CNW4850L/48100L Series 6KW Outdoor Solar Inverter With Lithium Battery Pack

Description

The CNW4850L/48100L Series 6KW Outdoor Solar Energy Storage Inverter is an integrated off-grid photovoltaic power supply device. It integrates an off-grid inverter module, lithium iron phosphate battery pack, PDU power distribution unit and high-protection outdoor cabinet. Professionally designed for harsh and complex outdoor working conditions, this product is widely applicable in suburban sites, remote roads, mountainous areas and more. It resists dust, moisture, rain and salt spray erosion, perfectly adapts to outdoor environments with unstable or poor grid power quality, and delivers stable pure sine wave AC power for outdoor precision equipment such as communication and network devices.

Feature:

  • Core Performance & Charging Advantages

Adopting full-digital double closed-loop control and SPWM modulation technology, the device outputs pure waveform and high-quality power. It supports uninterrupted dual-mode power supply including mains bypass and inverter output. Equipped with four intelligent charging modes (PV-only charging, mains priority, PV priority, hybrid PV and mains charging) and high-efficiency MPPT maximum power point tracking technology with a tracking efficiency of 99.9%, it maximizes photovoltaic energy utilization and achieves outstanding energy-saving performance.

  • Intelligent Operation & Energy Saving

Featuring comprehensive intelligent configurations, the device is equipped with an LCD screen and LED indicator lights to clearly display operating data and equipment status for easy maintenance. It supports a no-load power-saving mode and intelligent variable-speed cooling fans, which provide on-demand heat dissipation, reduce power consumption and effectively extend the service life of the equipment. In addition, it supports dual battery activation modes via mains electricity and PV, and is compatible with both lithium and lead-acid batteries to meet diverse energy storage configuration requirements.

  • Full Protection & Outdoor Adaptability

The whole unit is equipped with comprehensive safety protection functions, including overload, short circuit, over-voltage, under-voltage and reverse polarity protection, as well as dual AC and DC lightning protection to avoid circuit faults and lightning damage. Adopting an IP55 high-protection outdoor cabinet with an integrated welded structure, waterproof shutters, sun insulation and ventilation & dustproof structures, the equipment fully withstands harsh outdoor environments and ensures long-term stable operation.

  • Structural Advantages & Applications

With a modular design, the device features simple disassembly and convenient maintenance, greatly reducing later operation and maintenance costs. Boasting high protection level, intelligent performance, strong compatibility and excellent.

Technical Parameters

Model CNW4850L/CNW48100L-6KW
Inverter
Output format L+N+PE
Rated output power 6000W
Rated output voltage 220Vac/230Vac/240Vac±5%
Power factor 1.0
Output frequency range 50/60Hz±0.1%
Overload capacity(battery mode) 1min@102%~120%Load;10s@>120%Load
Harmonic distortion ≤3%(Linear load)
Peak efficiency >94%
Transfer time 10ms,20ms(Typical)
Grid voltage regulation (battery mode) ≤±5%(within the rated load range)
AC   Charge
Max.AC charge current 120A
DC   Charge
PV input voltage range 60-500VDC
PV Max.input power 9000W
MPPT tracking voltage range 60VDC-450VDC
Max.PV charge current 120A
Battery
Battery type LiFePO4
Rated capacity 50Ah    /100Ah
Nominal voltage 48VDC/51.2V
Cycle life 3500 cycles≥80%,25±2℃,1C/1C,80%DOD />4000 cycles 80%DOD
Environment
Humidity 20%to 95%(Non-condensing)
Altitude Less the 2000m
Operating temperature range -10℃~50℃
Storage temperature range -15℃~60℃
Physical
Net Weight(without battery) 69KG
Dimension:WxDxH(mm) 550x374x842
Communication interface USB/RS232/RS485/Dry Contact/Type-B/BMS
Dubai Traffic Light Project

Dubai Traffic Light Project

Dubai Road Monitoring Project

Dubai Road Monitoring Project

What does the whole system integration include?
The whole system integration includes an off-grid solar inverter module, lithium iron phosphate battery pack, PDU, and outdoor cabinet.
Can an inverter be installed outdoors?
There are many inverters for PV systems that can be installed outdoors. In fact, most grid-tied inverters are designed for outdoor use, although most off-grid inverters are not weatherproof and are generally mounted indoors, close to the battery bank. As a rule, inverters designed for outdoor use may be installed either outdoors or indoors, however indoor inverters can only be installed indoors. The great majority of grid-tied or string inverters available today are designed for outdoor installation. A survey of all the major manufacturers shows that nearly all of their products are encased either in NEMA 3R (protection against falling dirt, rain, sleet, and snow) or NEMA 4X (additional protection against windblown dust, splashing water, hose-directed water, and corrosion) enclosures. When choosing the site for installing an inverter, it is essential that the environmental conditions specified by the manufacturer be maintained. There are both temperature and humidity requirements for these devices. The installation must provide adequate ventilation and heat dissipation and the units must be protected from corrosive vapors or fine particles that may be present in some environments. For example, inverters should be kept away from such potential sources of vapor as swimming pool pumps or storage containers of chlorine. Apart from the manufacturer’s requirements for the units, there are also safety and other regulatory factors that must be considered. The inverter should not be located where it may be a hazard to people passing by it, such as in a narrow passageway. It also should not be located where it may be damaged by nearby activities or passing vehicles as may happen near the entrances of garages or workshops. These items are intended to make sure the installed equipment is appropriate for its location and doesn’t pose a hazard to anyone who might come into contact with it. Such issues as well as the requirement that all equipment be installed per the manufacturers’ instructions are explicit elements of the National Electrical Code. A final, but by no means less significant issue is that of inverter performance. Like most electronic devices, inverters operate more efficiently at cooler temperatures. While most grid-tied inverters are designed for outside installation, they should not be mounted in direct sunlight, as this will degrade their efficiency. In addition to the lost output, the lifetime of the unit is likely to be shortened. Even though PV financial models generally include inverter replacements over the lifetime of the system, designing an installation to prolong inverter life rather than shorten it is the most sensible strategy. Thus, even inverters that incorporate robust outdoor packaging should be kept shaded, even if it means installing an awning over them. The ideal installation site for inverters is cool, dry, dust-free and indoors. However, there are a growing number of applications for which this is impractical or undesirable. With appropriate system design, an outdoor inverter installation can be a reasonable and successful option.
How do I switch between the different charging modes?
Four charging modes available: PV only, mains priority, PV priority, PV & mains hybrid charging. Switch easily via LCD screen, the system automatically selects the optimal charging logic.

Related products

Three‑Phase Isolation Transformer 3KVA‑3000KVAThree‑Phase Isolation Transformer 3KVA‑3000KVA
Three‑Phase Isolation Transformer 3KVA‑3000KVA
Three-Phase Autotransformer
Three‑Phase Autotransformer 10KVA‑1000KVA
Single‑Phase Transformer 1KVA‑200KVA
Single‑Phase Transformer 1KVA‑200KVA
512V 100Ah High-Voltage LiFePO4 Battery System
CNLP512100-H 512V 100A High Voltage Lithium Battery System Backup Power

Related Articles

48V DC Telecom Power System vs Outdoor UPS Which Backup Architecture Fits a Remote
48V DC Telecom Power System vs Outdoor UPS: Which Backup Architecture Fits a Remote Site?
CONSNANT Industrial UPS Load Schedule Review
How to Choose an Industrial UPS for a Manufacturing Plant
CONSNANT Petrochemical Project Industrial UPS Installation
Industrial UPS for Oil & Gas Projects: What Should Buyers Specify?
CONSNANT Industrial UPS Main and Bypass Cabinets
Industrial UPS Maintenance Bypass: When Should a Project Specify a Separate Bypass Cabinet?

Contact us

Partner with CONSNANT to find the perfect power system for your business. Our technical team is ready to provide customized solutions to optimize power usage and maximize efficiency.

Solution5 1